Home>DCS>Emerson IC695PSA140J PACSystems RX3i Multi-Purpose Power Supply

Hot Categories

Emerson IC695PSA140J PACSystems RX3i Multi-Purpose Power Supply

Emerson IC695PSA140J PACSystems RX3i Multi-Purpose Power Supply

Item NO.: 3809490

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson IC695PSA140J PACSystems RX3i Multi-Purpose Power Supply
  • Item NO.3809490
  • Weight0.5200 kg = 1.1464 lb = 18.3425 oz
  • CategoryDCS
  • BrandEmerson
  • Creation Time2026-10-26
Emerson IC695PSA140J PACSystems RX3i Multi-Purpose Power Supply
PACSystems RX3iENGINEERING RECORD

LOAD SHARING · REDUNDANCY SUPPORT · REVISION J

Emerson IC695PSA140J PACSystems RX3i Multi-Purpose Power Supply

A 40 W, two-slot RX3i Universal Backplane supply for single, increased-capacity or redundant architectures.

Input classAC or high-voltage DC
ArchitectureLoad sharing / redundancy
Backplane widthTwo slots
01
EXACT EXECUTION

Product Identification

IC695PSA140J is the revision-J execution of the PACSystems RX3i 40 W multi-purpose supply. It accepts 85 to 264 VAC or 100 to 300 VDC and installs only in an IC695 Universal Backplane.

Unlike the PSA040 standard supply, the PSA140 supports load sharing and redundancy. One unit can serve as the sole rack supply, or a documented multi-supply design can provide greater capacity or redundancy within the manufacturer rules.

02
VERIFIED ATTRIBUTES

Engineering Data

Manufacturer
Emerson
Exact model
IC695PSA140J
Platform
PACSystems RX3i Universal Backplane
Supply type
40 W multi-purpose AC/DC power supply
Nominal input
120/240 VAC or 125 VDC
Input range
85 to 264 VAC; 100 to 300 VDC
Total load capacity
40 W
Backplane occupancy
Two slots
Input-to-backplane isolation
250 VAC continuous; 1500 VAC for one minute
Terminal wiring
14 to 22 AWG; one conductor per terminal
Status indicators
Power, P/S Fault, Overload, Overtemperature
Load sharing
Supported
Redundancy
Supported
Operating temperature
0 to 60 °C at inlet
Storage temperature
−40 to +85 °C
Humidity
5 to 95%, non-condensing
03
SYSTEM ROLE

Functions

A

Flexible supply architecture

Supports standalone use as well as engineered load-sharing and redundant arrangements.

B

Wide input acceptance

Operates from common plant AC services or a suitable 125 VDC-class source.

C

Four-condition indication

Local LEDs distinguish power availability, supply fault, overload and overtemperature states.

D

Universal Backplane integration

Uses the IC695 backplane for power distribution and controller fault reporting.

IndustryParts industrial automation support
INDUSTRIAL PARTS SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact identity before quotation

IndustryParts prepares IC695PSA140J enquiries around the complete manufacturer label, requested quantity and destination. For controlled replacements, include the host-system record, field photographs and configuration evidence that apply to this exact execution.

Complete labelRevision retainedApplication evidence
04
APPLICATION FIT

Applications

Redundant RX3i power

Pairing supplies under an approved architecture where continued rack power is required after one supply fault.

Increased-capacity rack

Sharing load when a single 40 W unit does not cover the documented module demand.

Single AC/DC source duty

Serving as the only supply where its two-slot footprint and 40 W capacity fit the rack plan.

05
MAINTENANCE RECORD

Lifecycle

01

Define the mode

Record whether the rack is single-supply, increased-capacity or redundant and capture all participating part numbers.

02

Verify installation

Check input source, two-slot placement, conductor size, grounding and load-sharing wiring.

03

Test the design

Confirm normal indicators and execute the approved overload, fault or redundancy proof appropriate to the rack architecture.

06
PRACTICAL REVIEW

FAQ

Q01

Can IC695PSA140J be used for RX3i redundant power?

Yes, the PSA140 supports redundancy, but the complete multi-supply arrangement and rack load must follow the manufacturer design rules.

Q02

How does IC695PSA140J differ from IC695PSA040?

IC695PSA140J is the multi-purpose version with load-sharing and redundancy support; the PSA040 is not a direct architectural equivalent.

Q03

What should accompany an IC695PSA140J quotation request?

Send the J revision label, Universal Backplane model, supply positions, input source, complete module list and calculated 40 W load budget.

Q04

Which IC695PSA140J indicators should be checked during commissioning?

Verify Power, P/S Fault, Overload and Overtemperature states under the approved operating and test conditions.

Q05

What proves a redundant IC695PSA140J installation is ready?

Normal load sharing, correct diagnostic status and a controlled proof that the rack remains powered after the approved single-supply isolation establish acceptance.

ENQUIRY INFORMATION

Send the complete IC695PSA140J label, requested quantity and destination.

You May Also Like