Home>DCS>Emerson IC695PSD040M PACSystems RX3i 24 VDC Power Supply

Hot Categories

Emerson IC695PSD040M PACSystems RX3i 24 VDC Power Supply

Emerson IC695PSD040M PACSystems RX3i 24 VDC Power Supply

Item NO.: 3809449

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson IC695PSD040M PACSystems RX3i 24 VDC Power Supply
  • Item NO.3809449
  • Weight0.2600 kg = 0.5732 lb = 9.1712 oz
  • CategoryDCS
  • BrandEmerson
  • Creation Time2026-10-26
Emerson IC695PSD040M PACSystems RX3i 24 VDC Power Supply
PACSystems RX3iPRODUCT RECORD

24 VDC INPUT · 40 W BACKPLANE POWER · REVISION M

Emerson IC695PSD040M PACSystems RX3i 24 VDC Power Supply

A single-slot RX3i DC power supply whose 40 W budget and nonredundant operating boundary must be preserved.

Input source24 VDC nominal
Backplane capacity40 W total
Installation widthOne slot
01
PRODUCT CONTEXT

Overview

IC695PSD040M is the revision-M execution of the PACSystems RX3i 24 VDC, 40 W power supply. It provides 5.1 VDC and 3.3 VDC backplane power plus a 24 VDC relay supply for compatible output-module circuits.

The module occupies one Universal Backplane slot and is not the multipurpose load-sharing version. Only one IC695PSD040 is permitted in a backplane, so an RX3i power-budget review is required before modules are added or exchanged.

02
CONTROLLED DATA

Specifications

Manufacturer
Emerson
Exact model
IC695PSD040M
Platform
PACSystems RX3i Universal Backplane
Input
24 VDC nominal
Operating input range
18 to 30 VDC
Startup input range
12 to 30 VDC
Total output capacity
40 W maximum
Backplane outputs
5.1 VDC and 3.3 VDC
Relay output supply
24 VDC
Module width
One slot
Parallel operation
Not supported
Redundancy mode
Not supported
Allowed quantity
One IC695PSD040 per Universal Backplane
Status reporting
Power-supply fault detection by the CPU
Revision identity
M suffix retained
03
FUNCTIONAL PROFILE

Features

A

Single-slot DC conversion

Uses one RX3i backplane position while converting the plant 24 VDC source into controller rails.

B

Three supply functions

Feeds the 5.1 V and 3.3 V backplane loads and the compatible 24 V relay circuits.

C

Fault visibility

Power-supply fault status is available to the RX3i CPU for system diagnostics.

D

Defined nonredundant role

The hardware boundary clearly separates this unit from multipurpose PSD140 load-sharing supplies.

IndustryParts industrial automation support
INDUSTRIAL PARTS SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact identity before quotation

IndustryParts prepares IC695PSD040M enquiries around the complete manufacturer label, requested quantity and destination. For controlled replacements, include the host-system record, field photographs and configuration evidence that apply to this exact execution.

Complete labelRevision retainedApplication evidence
04
FIELD USE

Applications

DC-powered RX3i controller

Supplying a Universal Backplane from a documented 24 VDC control-power source.

Single-slot migration constraint

Maintaining CPU slot position where a narrow DC supply is required.

Power-budget-controlled expansion

Supporting a rack whose combined 5.1 V, 3.3 V and relay loads remain inside 40 W.

05
SERVICE DISCIPLINE

Lifecycle

01

Calculate

Record the module-by-module RX3i power demand and the available 24 VDC source capacity.

02

Connect

Verify polarity, grounding, conductor size and overvoltage-protection jumper arrangement before energizing.

03

Monitor

Confirm POWER status, absence of supply faults and stable controller operation at expected rack load.

06
CUSTOMER QUESTIONS

FAQ

Q01

Can IC695PSD040M be paired with a second RX3i supply for redundancy?

No. The IC695PSD040 design is limited to one per Universal Backplane and does not support parallel or redundant operation.

Q02

What power record should accompany an IC695PSD040M enquiry?

Provide the complete rack module list, calculated 5.1 V and 3.3 V loads, relay demand, DC source rating and label photograph.

Q03

Why is input polarity important for IC695PSD040M?

The manufacturer warns that common external DC sources feeding multiple supplies must maintain identical polarity and a common system ground.

Q04

Does the M suffix change the need to verify IC695PSD040M compatibility?

No. Revision M must be retained in the installed record, and the host backplane plus rack load still determine suitability.

Q05

What checks close an IC695PSD040M replacement?

Verify input voltage and polarity, POWER indication, an empty CPU fault table for supply faults and stable operation under the documented rack load.

ENQUIRY INFORMATION

Send the complete IC695PSD040M label, requested quantity and destination.

You May Also Like