Home>DCS>Emerson KC3010X1-BK1 DeltaV S-Series 16-Channel HART Analog Input Card

Hot Categories

Emerson KC3010X1-BK1 DeltaV S-Series 16-Channel HART Analog Input Card

Emerson KC3010X1-BK1 DeltaV S-Series 16-Channel HART Analog Input Card

Item NO.: 3790456

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson KC3010X1-BK1 DeltaV S-Series 16-Channel HART Analog Input Card
  • Item NO.3790456
  • Weight0.1800 kg = 0.3968 lb = 6.3493 oz
  • CategoryDCS
  • BrandEmerson
  • Creation Time2026-10-13
DeltaV S-series | 16 analog inputs | HART Plus

Emerson KC3010X1-BK1 DeltaV S-Series 16-Channel HART Analog Input Card

A sixteen-channel 4–20 mA HART input card whose BK1 execution, carrier keying and complete loop map must stay together.

BrandEmerson
ModelKC3010X1-BK1
Product TypeDeltaV S-Series 16-Channel 4–20 mA HART Analog Input Card
01

Overview

KC3010X1-BK1 identifies an Emerson DeltaV S-series Plus analog input card for sixteen 4–20 mA channels with HART communication. It acquires process current and supports HART device information through the DeltaV I/O architecture.

The BK1 suffix distinguishes this exact S-series execution from visually similar DeltaV M-series and other Plus cards. Ordering and replacement should use the complete label, associated carrier or terminal assembly, controller release and the installed channel database.

02

Specs

Manufacturer Emerson DeltaV
Exact Model KC3010X1-BK1
Product Family DeltaV S-series I/O
Product Type 16-channel analog input card
Signal Standard 4–20 mA
Digital Communication HART
Channel Count 16
Architecture DeltaV Plus I/O card
Series Boundary S-series execution; do not substitute the M-series KC3010X1-BA2 by appearance
Carrier / Terminal Requirement Must match the documented S-series installation and keying
Configuration Record Channel tag, range, square-root or linear processing, alarm limits and HART identity
Environmental / Approval Boundary Confirm from the complete installed label and site classification
Replacement Basis Exact KC3010X1-BK1 label, DeltaV release and carrier relationship
03

Features

01

Sixteen current loops consolidate analog acquisition in one DeltaV I/O position.

02

HART support carries device diagnostics and identification alongside the process variable.

03

Plus-card architecture integrates channel status with the DeltaV controller database.

04

Exact suffix control prevents accidental interchange with a different series or termination route.

04

Applications

  • DeltaV process inputs from pressure, flow, level and temperature transmitters.
  • Brownfield S-series maintenance where HART asset information must remain available.
  • Revision-controlled spare replacement using the existing carrier and channel database.
05

Lifecycle

  • Export the DeltaV I/O configuration, channel alarms, HART device list and control-module references.
  • Photograph the card, carrier and field-terminal labels before removal.
  • Confirm field-power ownership and make loops safe under the site permit before disturbing hardware.
  • Compare keying and installed-series documentation rather than using connector fit as proof of compatibility.
  • After replacement, verify every 4–20 mA value, bad-status behavior, HART communication and dependent control-module alarm.
06

FAQ

Can an M-series Plus card replace KC3010X1-BK1?

No automatic equivalence should be assumed. The BK1 label identifies an S-series execution with its own carrier and installation boundary.

What information is needed to quote KC3010X1-BK1 accurately?

Provide the full card and carrier labels, DeltaV software release, controller context, channel count in use and hazardous-area requirements.

Why can a process value work while HART data is missing on KC3010X1-BK1?

Loop resistance, field power, HART filtering, device configuration or the controller database can block digital communication while the 4–20 mA signal remains valid.

How should KC3010X1-BK1 be accepted after replacement?

Inject or observe every loop, verify scaling and alarms, confirm bad-status handling and check the HART identity and diagnostics for connected devices.

What records reduce risk during a KC3010X1-BK1 outage?

Retain the channel-to-terminal map, loop drawings, transmitter tags, ranges, HART addresses, alarm settings and a DeltaV database backup.

You May Also Like