  • Product NameEmerson KJ3245X1-BK1 DeltaV S-Series AS-Interface Card
  • Item NO.3814254
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandEmerson
  • Creation Time2026-10-30
AS-INTERFACE CARD · D1 KEYING · 12 V DC LOCAL BUS

Emerson KJ3245X1-BK1 DeltaV S-Series AS-Interface Card

An S-Series AS-Interface card with a 12 V DC local-bus demand of 300 mA and defined hazardous-area service limits.

InterfaceAS-Interface
Local-bus power12 V DC at 300 mA
Terminal keyD1
01
ASSET RECORD

Product Identification

KJ3245X1-BK1 is the Emerson DeltaV S-Series AS-Interface Card. The manufacturer instruction sheet identifies a 12 V DC local-bus requirement at 300 mA and rotary terminal-block key position D1.

The card is installed as part of a controlled AS-i network rather than as a generic digital I/O replacement. Segment topology, connected devices, network supply and addressing records must stay with the module service file.

The D1 terminal key and complete BK1 suffix define the physical service boundary for the AS-i interface card.
02
CONFIGURATION REGISTRY

Engineering Data

Product type
S-Series AS-Interface Card
Network role
AS-Interface connection
Local-bus power
12 V DC at 300 mA
Terminal-block key
D1
Ambient temperature
−25 to +70 °C
Relative humidity
5 to 95%, non-condensing
Shock
10 g half-sine, 11 ms
Vibration
1 mm peak-to-peak from 2 to 13.2 Hz; 0.7 g from 13.2 to 150 Hz
Airborne contaminants
ISA-S71.04 Class G3
Calibration
Not required
03
OPERATING ROLE

Functions

01

Connect the AS-i segment

Provides the identified DeltaV card function for the installed Actuator Sensor Interface network.

02

Maintain keyed termination

D1 rotary keying keeps the card aligned with the intended terminal block.

03

Report within the controller architecture

The card participates in the DeltaV S-Series carrier and diagnostic environment.

04
FIELD PLACEMENT

Applications

Sensor and actuator segment

Use only where the installed AS-i topology, power unit and addressed devices match the control design.

Controlled modernization

Preserve the original node list and addressing when the interface card is exchanged during maintenance.

Approved hazardous location

Apply the site enclosure and installation instructions associated with the card approvals.

05
MAINTENANCE CONTROL

Lifecycle

01

Survey

Record KJ3245X1-BK1, the D1 terminal block, AS-i power source, segment cable and connected node list.

02

Isolate

Remove system and field power under the approved DeltaV and site procedure.

03

Restore

Refit the keyed termination and restore the documented network settings without changing addresses.

04

Confirm

Verify segment health, node communication, diagnostics and all affected control functions.

IndustryParts industrial parts support
INDUSTRIAL SPARE-PART SUPPORT

About IndustryParts

https://www.industryparts.com/

Controlled handling for KJ3245X1-BK1

IndustryParts keeps the submitted KJ3245X1-BK1 identity, requested quantity and installed-system evidence together so a proposed supply can be checked before dispatch.

  • Suffix and MOD identity kept visible
  • Mating hardware recorded before supply
  • Acceptance evidence linked to the order
07
PURCHASE AND SERVICE SUPPORT

FAQ

Q01

What network role does KJ3245X1-BK1 perform?

Emerson identifies it as an S-Series AS-Interface Card for the installed AS-i segment.

Q02

How much local-bus power does KJ3245X1-BK1 require?

The manufacturer instruction sheet specifies 12 V DC at 300 mA.

Q03

What should accompany a KJ3245X1-BK1 request?

Provide the BK1 label, D1 terminal key, carrier slot, AS-i topology, power-unit identity and node list.

Q04

Can KJ3245X1-BK1 be inserted with the carrier energized?

No. Emerson states that the unit cannot be removed or inserted with system power energized.

Q05

What proves KJ3245X1-BK1 is ready after exchange?

Document correct card recognition, healthy segment voltage, communication with every expected node and successful function tests.