Home>DCS>Emerson KJ3246X1-BA1 DeltaV S-Series H1 Fieldbus Interface with Integrated Power

Hot Categories

Emerson KJ3246X1-BA1 DeltaV S-Series H1 Fieldbus Interface with Integrated Power

Emerson KJ3246X1-BA1 DeltaV S-Series H1 Fieldbus Interface with Integrated Power

Item NO.: 3814256

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson KJ3246X1-BA1 DeltaV S-Series H1 Fieldbus Interface with Integrated Power
  • Item NO.3814256
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandEmerson
  • Creation Time2026-10-30
H1 FIELDBUS · TWO PORTS · INTEGRATED SEGMENT POWER

Emerson KJ3246X1-BA1 DeltaV S-Series H1 Fieldbus Interface with Integrated Power

A DeltaV S-Series H1 fieldbus interface providing two powered ports, with 12 V DC local-bus demand and defined field-circuit limits.

FieldbusFOUNDATION Fieldbus H1
S-Series port count2 powered ports
Local-bus demand12 V DC at 300 mA
01
ASSET RECORD

Product Identification

KJ3246X1-BA1 is the Emerson DeltaV S-Series H1 Fieldbus Interface Module with integrated segment power. The S-Series execution provides two fieldbus ports and is identified by the complete BA1 suffix.

Manufacturer certification data lists 12 V DC local-bus power at 300 mA and field-circuit power of 28–30 V DC at up to 400 mA per port. Segment design, terminators, cable loading and connected devices remain part of the compatibility decision.

This BA1 article is the two-port S-Series execution with integrated fieldbus segment power; it is not selected by H1 terminology alone.
02
CONFIGURATION REGISTRY

Engineering Data

Product type
H1 Fieldbus Interface Module
Series execution
DeltaV S-Series
Port count
2
Integrated power
Yes
Local-bus power
12 V DC at 300 mA
Field-circuit voltage
28–30 V DC
Field-circuit current
Up to 400 mA per port
Service identity
Complete BA1 suffix required
Network record
Segment topology and device list required
Fieldbus class
FOUNDATION Fieldbus H1
03
OPERATING ROLE

Functions

01

Interface H1 devices

Connects the DeltaV controller architecture to the installed FOUNDATION Fieldbus H1 segments.

02

Power two segments

Integrated power supports the two S-Series ports within the stated field-circuit ratings.

03

Keep segment diagnostics visible

Interface status and network evidence support service decisions for each connected segment.

04
FIELD PLACEMENT

Applications

Powered H1 segments

Use where the segment current, cable, terminators and field devices remain within the approved design.

Process-instrument communication

Retain device tags, schedules and control strategies when the interface is replaced.

Controlled spare exchange

Match the two-port BA1 hardware identity instead of assuming equivalence with M-Series or four-port versions.

05
MAINTENANCE CONTROL

Lifecycle

01

Map

Record KJ3246X1-BA1, both port assignments, segment currents, terminators and every connected field device.

02

De-energize

Isolate controller and fieldbus power in the order required by the approved process procedure.

03

Reconnect

Restore each segment to its original port and preserve shield, spur and terminator arrangements.

04

Validate

Confirm stable segment voltage, expected devices, communication quality and all affected control strategies.

IndustryParts industrial parts support
INDUSTRIAL SPARE-PART SUPPORT

About IndustryParts

https://www.industryparts.com/

Controlled handling for KJ3246X1-BA1

IndustryParts keeps the submitted KJ3246X1-BA1 identity, requested quantity and installed-system evidence together so a proposed supply can be checked before dispatch.

  • Suffix and MOD identity kept visible
  • Mating hardware recorded before supply
  • Acceptance evidence linked to the order
07
PURCHASE AND SERVICE SUPPORT

FAQ

Q01

How many H1 ports are associated with KJ3246X1-BA1?

The S-Series execution is identified as a two-port fieldbus interface with integrated segment power.

Q02

What power data matters for KJ3246X1-BA1?

Retain the 12 V DC / 300 mA local-bus requirement and the 28–30 V DC field-circuit rating up to 400 mA per port.

Q03

What should accompany a KJ3246X1-BA1 quotation?

Provide the BA1 label, carrier slot, two-port segment map, measured segment currents and field-device schedule.

Q04

Can KJ3246X1-BA1 replace a four-port fieldbus interface?

Not by family name alone. Port count, series, integrated-power architecture and controller compatibility must match.

Q05

What closes a KJ3246X1-BA1 service record?

Document correct module recognition, both segment voltages, discovery of all expected devices and successful loop or strategy tests.