  • Product NameEmerson PR6424/003-130 16 mm Eddy Current Sensor
  • Item NO.3813272
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandEpro
  • Creation Time2026-10-29
16 MM TIP · M18 × 1.5 · 8 M CABLE WITH LEMO END

Emerson PR6424/003-130 16 mm Eddy Current Sensor

A non-contact large-shaft sensor configured without armor or adaptor plug and with an 8 m LEMO-ended cable.

Ordering code 003M18 thread, no armor, 70 mm Cx
Ordering code 130No adaptor plug, 8 m, LEMO
Nominal sensitivity4 V/mm
01
PRODUCT DOSSIER

Product Overview

PR6424/003-130 is an Emerson PR6424 16 mm eddy current sensor for non-contact measurement on large ferromagnetic shafts. The family supports radial and axial dynamic displacement, position, eccentricity and speed or key measurements.

The official order matrix decodes the submitted execution as M18 × 1.5 thread, no armored cable and Cx length code 3 at 70 mm. Suffix 130 selects no adaptor plug, an 8 m total cable and a LEMO cable end.

The sensor must operate with the approved converter and target material. Gap, extension components, converter calibration and hazardous-area approval are system-level decisions rather than properties of the probe label alone.

02
PUBLISHED CHARACTERISTICS

Performance

SIGNAL

Non-contact shaft measurement

Observes displacement or position without mechanical contact with the rotating target.

TRANSFER

Large-shaft application

Uses the 16 mm sensor family intended for ferromagnetic shafts at least 80 mm in diameter.

CONTROL

Dynamic and static response

Supports position and vibration ranges defined for the matched PR6424 measurement chain.

EVIDENCE

Harsh-machine construction

Uses a stainless-steel sleeve and PTFE cable with published pressure and vibration resistance.

03
ENGINEERING RECORD

Technical Details

Manufacturer
Emerson
Exact model
PR6424/003-130
Sensor family
PR6424 16 mm eddy current sensor
Static range
±2.0 mm
Dynamic range
0 to 1,000 µm
Nominal center air gap
Approximately 2.7 mm
Linearity
≤ ±1.5%
Target material
Ferromagnetic steel, 42CrMo4 standard
Minimum shaft diameter
80 mm
Maximum surface speed
2,500 m/s
Operating temperature
−35 to +150 °C
Sensor-head pressure resistance
10,000 hPa
Sleeve / cable materials
Stainless steel / PTFE
Weight reference
Approximately 200 g for sensor with 1 m cable, no armor
DOCUMENTED INDUSTRIAL SUPPLY

About IndustryParts

https://www.industryparts.com/

The full sensor suffix controls mechanical and cable fit

IndustryParts keeps the PR6424 thread, body length, cable construction, connector and converter evidence together before a proposed sensor is released.

IndustryParts industrial automation supply support
04
SYSTEM PATH

System Integration

CAPTURE

Verify the complete chain

Match sensor, cable end, converter model and target material before setting the operating gap.

MATCH

Protect the unarmored lead

Route the 8 m PTFE cable with appropriate support, bend radius and separation from damage sources.

PROVE

Establish calibrated response

Set the approved gap and verify bias, travel and dynamic response with the receiving monitor or converter.

05
FIELD CONTEXT

Applications

Large rotating shafts

Measuring vibration and position on turbines, compressors, pumps and fans.

Axial or radial observation

Supporting approved displacement geometry with the matched converter.

Speed or key reference

Providing a non-contact reference signal where the mechanical arrangement is validated.

06
PROCUREMENT SUPPORT

FAQ

QUESTION 01

What mechanical execution is encoded by PR6424/003-130?

The 003 fields specify M18 × 1.5 thread, no armor and the 70 mm Cx length code.

QUESTION 02

What cable execution is encoded by PR6424/003-130?

The 130 suffix selects no adaptor plug, 8 m total cable and a LEMO end.

QUESTION 03

Can PR6424/003-130 be used with any eddy-current converter?

No. Converter type, calibration, range and approval must be compatible with the PR6424 measurement chain.

QUESTION 04

What target evidence should accompany PR6424/003-130?

Provide shaft material, diameter, surface condition, measurement direction, expected travel and installed gap.

QUESTION 05

What proves PR6424/003-130 is ready after installation?

A stable bias or gap value, verified travel, correct scaling and the required dynamic or speed test complete the record.