Home>DCS>Emerson PR6424/010-100 16 mm Eddy Current Sensor

Hot Categories

Emerson PR6424/010-100 16 mm Eddy Current Sensor

Emerson PR6424/010-100 16 mm Eddy Current Sensor

Item NO.: 3806693

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson PR6424/010-100 16 mm Eddy Current Sensor
  • Item NO.3806693
  • Weight0.7500 kg = 1.6535 lb = 26.4555 oz
  • CategoryDCS
  • BrandEpro
  • Creation Time2026-10-23
M18 × 1.5 · ARMORED CABLE · 40 MM SLEEVE CODE

Emerson PR6424/010-100 16 mm Eddy Current Sensor

A 16 mm eddy current sensor configured with M18 × 1.5 thread, armored cable and a 4 m lead ending in LEMO termination.

Nominal sensitivity4 V/mm
Static range±2.0 mm
Cable code4 m, LEMO
PRODUCT DOSSIER

Product Profile

01
PRODUCT / SYSTEM CONTEXT

PR6424/010-100

A 16 mm eddy current sensor configured with M18 × 1.5 thread, armored cable and a 4 m lead ending in LEMO termination.

Emerson PR6424/010-100 is a PR6424 16 mm eddy current sensor for non-contact measurement of shaft displacement, position, eccentricity and speed/key targets in critical rotating machinery.

The exact suffix decodes the mechanical and cable execution: M18 × 1.5 sleeve thread, armored cable, 40 mm sleeve code, no adaptor plug, 4 m total cable and a LEMO cable end.

Emerson treats the sensor, cable and matching converter as a calibrated measurement chain. The target material, converter identity and installed gap must therefore remain in the service record.

PUBLISHED EVIDENCE

Technical Data

02
Manufacturer
Emerson
Exact model
PR6424/010-100
Sensor family
PR6424, 16 mm eddy current sensor
Sleeve thread
M18 × 1.5
Cable armor
With armor
Sleeve code
40 mm Cx; total C = Cx + 12.5 mm
Adaptor plug
Without
Total cable length
4 m
Cable end
LEMO
Nominal sensitivity
4 V/mm
Static range
±2.0 mm
Dynamic range
0–1000 µm
Nominal center air gap
Approximately 2.7 mm
Target material
Ferromagnetic steel, 42CrMo4 standard
Minimum shaft diameter
80 mm
Operating temperature
−35 to 150 °C
Sensor-head pressure resistance
10,000 hPa
Sleeve / cable material
Stainless steel / PTFE
CONTROLLED PATH

System Role

03
01

Record the complete chain

Capture PR6424/010-100, converter reference, channel setup, target material, bracket and cold-gap measurement.

02

Protect the armored route

Maintain bend radius, connector cleanliness, cable restraint and separation from interference sources.

03

Verify the measurement

Check gap voltage, direction, range, alarm behavior and machine protection response under the approved procedure.

MATCH CRITERIA

Compatibility

04

Non-contact shaft measurement

The probe observes a ferromagnetic target without mechanical contact.

Encoded mechanical build

Thread, armor, sleeve length, cable length and termination are all fixed by the complete suffix.

API 670 measurement characteristics

Emerson publishes the temperature-error statement for API 670 compliant use.

Calibrated chain requirement

Sensor, extension connection where applicable and converter must match the approved measuring chain.

FIELD DUTY

Applications

05
FIELD CONTEXT

Radial shaft vibration

Measuring shaft motion on turbines, compressors, pumps and fans.

FIELD CONTEXT

Axial position monitoring

Tracking controlled shaft position with the documented target geometry and installed gap.

FIELD CONTEXT

Speed or key reference

Using the eddy-current response with the converter and monitoring channel designed for the key signal.

IndustryParts industrial automation support
CONTROLLED INDUSTRIAL SUPPLY

About IndustryParts

https://www.industryparts.com/

Application evidence stays with PR6424/010-100

IndustryParts keeps the requested model, quantity, label evidence and delivery record together so the proposed supply can be reviewed against the real installed application before dispatch.

Exact label recorded
System evidence reviewed
Dispatch identity retained
PROCUREMENT QUESTIONS

FAQ

06
Q01

What must accompany a PR6424/010-100 sensor enquiry?

Provide the complete probe label, converter model and serial data, target material, shaft diameter, bracket, measured gap and cable-route photographs.

Q02

Which thread and cable construction belong to PR6424/010-100?

The ordering code selects an M18 × 1.5 thread, armored cable, 4 m total cable and LEMO termination.

Q03

Can PR6424/010-100 be evaluated without its converter?

Not as a complete measurement chain. Emerson supplies PR642x sensors for use with the matching calibrated CON0x1 converter arrangement.

Q04

What target geometry is published for PR6424/010-100?

The PR6424 data specifies ferromagnetic 42CrMo4 reference material and a shaft diameter of at least 80 mm.

Q05

What should be retained after installing PR6424/010-100?

Keep the gap-voltage result, mechanical clearance, cable inspection, channel scaling, alarm checks and final machinery-protection test record.

ENQUIRY INFORMATION

Send the complete PR6424/010-100 label, requested quantity and delivery destination.

WHATSAPP / PHONE+86 18030175807

You May Also Like