Provides a nominal 4 V/mm sensitivity with a stated tolerance of no more than ±1.5%.
Product Overview
PR6424/011-110 is an Emerson 16 mm eddy-current sensor configuration for non-contact vibration and position measurement on rotating machinery.
The complete ordering code specifies an M18 × 1.5 sleeve thread, armored cable, 50 mm case dimension, no adapter plug, 5.0 m total cable and a LEMO cable end.
Performance
Supports a static measuring span of ±2.0 mm and dynamic movement from 0 to 1000 µm.
Uses a 2.7 mm center gap with the referenced 42CrMo4 ferromagnetic-steel target.
Accommodates large-shaft applications with a documented minimum shaft diameter of 80 mm.
Technical Details
| Manufacturer | Emerson |
|---|---|
| Sensor family | PR6424, 16 mm eddy current |
| Mechanical configuration | M18 × 1.5; armored; 50 mm case dimension |
| Cable configuration | 5.0 m total cable; LEMO end; no adapter plug |
| Sensitivity | 4 V/mm, ≤ ±1.5% |
| Center gap | 2.7 mm |
| Static measuring range | ±2.0 mm |
| Dynamic measuring range | 0 to 1000 µm |
| Temperature drift | < 0.3% |
| Reference target | 42CrMo4 ferromagnetic steel |
| Minimum shaft diameter | 80 mm |
| Maximum surface speed | 2500 m/s |
| Operating temperature | -35 to +150 °C |
| Sensor-head pressure capability | 10,000 hPa |
| Primary materials | Stainless-steel sleeve and PTFE cable |
System Integration
- Verify M18 × 1.5 mounting, available case depth and cable bend path before installing PR6424/011-110.
- Pair the sensor only with the documented converter and monitor channel for the PR6424 calibration system.
- Set the operating gap electrically against the approved target material and retain the final gap voltage.
- Protect the 5 m armored lead and LEMO termination from strain, contamination and high-energy cable routes.
Applications
- Relative shaft vibration and position measurement on large rotating-machine shafts.
- Machinery protection channels requiring the PR6424 16 mm measurement geometry.
- Replacement of the exact armored, 5 m, no-adapter configuration after mechanical and converter checks.
FAQ
What distinguishes PR6424/011-110 from nearby PR6424 codes?
The exact code fixes the M18 × 1.5 thread, armor, 50 mm case dimension, absence of an adapter plug, 5 m cable and LEMO end.
Can PR6424/011-110 be used on a shaft smaller than 80 mm?
The manufacturer data specifies an 80 mm minimum shaft diameter for the stated performance; a smaller target requires engineering review.
What must match when replacing PR6424/011-110?
Confirm mechanical code, cable length and end, target material, converter family, monitor scaling and the installed gap procedure.
How should PR6424/011-110 be routed near the machine?
Respect the armored-cable bend requirement, secure the lead without crushing it and keep the signal route separated from high-energy switching conductors.
Which commissioning values should be saved for PR6424/011-110?
Record gap voltage, slow-roll runout, channel scale, alarm settings, converter identity and measured loop behavior.
About IndustryParts
https://www.industryparts.com/Mechanical code and calibration path reviewed together
IndustryParts keeps PR6424/011-110 tied to its mounting, cable and matched-converter details for a usable replacement record.
- Mounting geometry checked
- 5 m code retained
- Calibration path identified
Recommended Models
| MCR-SL-S-1-5-I-DCI-230 | ABB DC522 1SAP440600R0001 | HG 71910VC |
| 0-70 bar /0-1000 | MCH40A0150-503-4-00 | 6SE1133-4WB00 |
| Schneider 140CRP93100 | VFG35 DN25 | BRS20-8TX |
| CDC-START | OT115/R | 4PP065.IF23-1 |
| HDCM1 | DSBG-50-80-PPVA-N3-128V | 750-342 |
| 1SAP520200R0001 | FA47 DRE80M4BE1/IS/TH/AS7W | MK5350 |
| Nokia 3HE04324ABAA02 | 6FC5850-3YG21-4YA0-Z | MAC93B-0-GS-3-C/110-A-0/S07 |
| X05V-K 1X0.75 4512262S | 0AC240.9 | Joke G300 |
| CIF50-DNM | Honeywell TC809B1008 | 3VU1300-0FM00 |