Home>PLC>GE IS200TDBTH2ABC Discrete I/O Terminal Board

Hot Categories

GE IS200TDBTH2ABC Discrete I/O Terminal Board

GE IS200TDBTH2ABC Discrete I/O Terminal Board

Item NO.: 3787257

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameGE IS200TDBTH2ABC Discrete I/O Terminal Board
  • Item NO.3787257
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandGE General Electric
  • Creation Time2026-10-09
GE MARK VIe | TDBT H2 | TMR DISCRETE I/O

GE IS200TDBTH2ABC Discrete I/O Terminal Board

A TDBT H2 revision board for TMR discrete field termination with 24 contact inputs and 12 form-C relay outputs.

BrandGE
ModelIS200TDBTH2ABC
Product TypeMark VIe TDBT Discrete I/O Terminal Board
01

Product Overview

IS200TDBTH2ABC is a GE TDBT discrete input/output terminal board for Mark VIe turbine-control systems. The complete H2ABC identity denotes the H2 hardware group and its revision trail, which must be preserved during sourcing and receiving.

The TDBT design is used for TMR operation with three PDIO I/O packs. It terminates 24 group-isolated contact inputs and 12 form-C relay outputs, with pluggable terminal blocks and noise suppression at the field interface.

02

Performance

  • Twenty-four contact inputs use the H2 nominal 24 VDC wetting-voltage configuration.
  • The documented H2 input range is 16 to 32 VDC from a floating external wetting source.
  • Twelve form-C relay outputs provide discrete control functions.
  • Three D-type PDIO connection points support the R, S and T controller paths.
  • Input filtering suppresses surge and high-frequency noise near the field entry point.
03

Technical Details

Manufacturer GE
Model IS200TDBTH2ABC
Functional Acronym TDBT
Hardware Group H2
Product Type Discrete input/output terminal board
System Family Mark VIe turbine control
Architecture TMR
Contact Inputs 24, group isolated
Nominal Input Wetting Voltage 24 VDC
Input Wetting Range 16 to 32 VDC, floating source
Relay Outputs 12 form-C
I/O Pack Interface Three PDIO connection points
Connector Style D-type connectors for I/O packs
Field Terminals Pluggable terminal blocks
Input Protection Surge and high-frequency noise suppression
Mounting DIN-rail or flat mounting
Revision Identity ABC suffix retained
Compatibility Control Confirm PDIO versions, WROB option use, wetting supply and system guide revision
04

System Integration

  • Export the discrete I/O configuration, relay logic, diagnostics, wetting-supply details and redundancy state.
  • Photograph the IS200TDBTH2ABC label, terminal blocks, PDIO connectors, option hardware and every field conductor.
  • Place the turbine controls in the approved maintenance state and isolate field and relay energy.
  • Rebuild the wiring from a checked I/O schedule, including commons, shields and the floating wetting source.
  • Prove all 24 inputs, 12 relay outputs, PDIO paths, diagnostics and TMR behavior before release.
05

Applications

  • TMR contact-input termination in Mark VIe gas- and steam-turbine controls.
  • Discrete permissive, status and alarm acquisition with 24 VDC wetting.
  • Form-C relay interfacing for auxiliary and control functions.
  • Revision-controlled support of installed TDBT H2 terminal-board assemblies.
06

FAQ

What should be supplied with an IS200TDBTH2ABC quotation request?

Provide the full H2ABC label, Mark VIe cabinet and controller identity, all three PDIO models, terminal and cable photographs, wetting-supply record and any WROB option details.

Can IS200TDBTH2ABC operate correctly with only one PDIO pack?

The TDBT architecture is documented for redundant/TMR operation; do not treat it as a simplex board without an engineering review of the complete system.

How should the floating 24 VDC wetting source for IS200TDBTH2ABC be checked?

Measure source voltage, polarity and insulation to ground under load, then verify input thresholds and ground-fault monitoring against the site drawings.

What is the acceptance test for IS200TDBTH2ABC relay outputs?

Prove each form-C contact under an approved test load, verify feedback and diagnostics through all PDIO paths, and confirm no unintended turbine-control action.

Can a different TDBT H-group replace IS200TDBTH2ABC?

Only after input voltage, relay arrangement, PDIO compatibility, option-board use, mounting and the exact GE system documentation have been compared.