Home>PLC>HIMA X-SB 01 System Bus Module

Hot Categories

HIMA X-SB 01 System Bus Module

HIMA X-SB 01 System Bus Module

Item NO.: 3806692

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameHIMA X-SB 01 System Bus Module
  • Item NO.3806692
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandHIMA
  • Creation Time2026-10-23
HIMAX SYSTEM BUS · SIL 3 PLATFORM · REDUNDANT SAFETY ARCHITECTURE

HIMA X-SB 01 System Bus Module

The HIMax system bus module used with the designated base plate inside HIMA fault-tolerant safety-system architecture.

Module roleSystem bus
Safety platformHIMax
Published SIL level3
01
PRODUCT RECORD

Overview

HIMA X-SB 01 is the system bus module in the HIMax modular safety platform. HIMA lists it as a SIL 3 component and pairs it with the X-BASE PLATE 01.

The module participates in the internal system architecture that supports the HIMax processor, communication and I/O population. It is not a field I/O module and does not replace an X-COM or X-CPU function.

A controlled service record should include the full rack architecture, base plate, module version, approved firmware context and SILworX project evidence.

02
MANUFACTURER DATA

Specifications

Manufacturer
HIMA
Exact model
X-SB 01
Platform
HIMax
Module type
System bus module
Published safety level
SIL 3
Associated base plate
X-BASE PLATE 01
Common module envelope
310 × 29 × 230 mm
Engineering environment
SILworX
System architecture
Modular fault-tolerant safety system
Firmware control
Use the approved HIMax device and firmware revision list
03
ENGINEERING CHARACTER

Features

A

Dedicated bus role

The module provides the named HIMax system-bus function rather than field-signal acquisition or protocol conversion.

B

Safety-system integration

Its use belongs to the certified HIMax architecture and the approved SILworX configuration.

C

Base-plate dependency

HIMA identifies X-BASE PLATE 01 as the base plate for this system bus module.

D

Version-governed maintenance

Hardware and safety-related operating-system revisions must follow the applicable approved device list.

04
APPLICATION FIT

Applications

FIELD CONTEXT

Emergency shutdown systems

Supporting the HIMax internal architecture used for a validated ESD application.

FIELD CONTEXT

Fire and gas protection

Maintaining the system bus within a certified HIMax fire-and-gas control system.

FIELD CONTEXT

High-integrity process protection

Serving the modular safety platform used for HIPPS, burner control or other approved critical-control duties.

05
SERVICE DISCIPLINE

Lifecycle

RECORD

Capture the HIMax architecture

Record X-SB 01, base plate, rack position, processor modules, firmware list and SILworX project before service.

MATCH

Use the approved replacement process

Follow HIMA instructions for module exchange, redundancy state and system availability.

PROVE

Complete the safety acceptance

Confirm diagnostics, system communication, redundancy behavior and the authorized application proof tests.

CONTROLLED INDUSTRIAL SUPPLY

About IndustryParts

https://www.industryparts.com/

Application evidence stays with X-SB 01

IndustryParts keeps the requested model, quantity, label evidence and delivery record together so the proposed supply can be reviewed against the real installed application before dispatch.

Exact label recorded
System evidence reviewed
Dispatch identity retained
IndustryParts industrial automation support
06
BUYER SUPPORT

FAQ

Q01

What should accompany a X-SB 01 enquiry?

Provide the module and X-BASE PLATE 01 labels, hardware revision, rack position, HIMax firmware list, SILworX release and architecture drawing.

Q02

Is X-SB 01 a communication protocol module?

No. HIMA identifies it as the system bus module; protocol communications are handled by the X-COM family.

Q03

Which base plate is associated with X-SB 01?

HIMA lists X-BASE PLATE 01 as the base plate for this system bus module.

Q04

Why must firmware evidence be retained for X-SB 01?

The safety-related system bus operating system and hardware version must remain within the approved HIMax device and firmware configuration.

Q05

How is X-SB 01 accepted after replacement?

Confirm correct hardware recognition, healthy system diagnostics, stable internal communication, required redundancy and all authorized safety acceptance tests.

ENQUIRY INFORMATION

Send the complete X-SB 01 label, requested quantity and delivery destination.

WHATSAPP / PHONE+86 18030175807

You May Also Like