Home>DCS>Hollysys K-CU11 Main Controller Module

Hot Categories

Hollysys K-CU11 Main Controller Module

Hollysys K-CU11 Main Controller Module

Item NO.: K-CU11

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameHollysys K-CU11 Main Controller Module
  • Item NO.K-CU11
  • Weight0.0000 kg = 0.0000 lb = 0.0000 oz
  • CategoryDCS
  • BrandHollysys
  • Creation Time2026-08-17
  • HOLLiAS MACS-K main controller supporting redundant control, network resilience and large I/O capacity.
HOLLYSYS HOLLIAS MACS-K CONTROLLER

K-CU11

HOLLiAS MACS-K main controller supporting redundant control, network resilience and large I/O capacity.

Product Profile

K-CU11 is a Hollysys main controller for the HOLLiAS MACS-K distributed control system. It is designed for field control stations within the MACS system architecture, coordinating control logic, I/O data and communication across the controller domain.

Hollysys documents redundant controller configuration together with redundancy for both the CNET control network and SNET system network.

Technical Data

Manufacturer Hollysys
Model K-CU11
System family HOLLiAS MACS-K DCS
Controller role Main controller module
CPU architecture 32-bit PowerPC
Clock frequency 400 MHz
Internal memory 128 MB
Maximum I/O modules 100
Maximum I/O points 3,200
PID loop capacity 300
Redundancy Controller, CNET and SNET redundancy supported
Integrity feature ECC verification
Security processor SM3 encryption algorithm processor

System Role

Within the HOLLiAS architecture, management, system and control networks are separated into MNET, SNET and CNET layers. K-CU11 operates in the field control station layer and coordinates connected I/O modules through the system's controller and I/O-bus architecture.

The controller is based on the K-CU01 generation and adds an SM3 encryption processor plus expanded storage used for trusted boot and dynamic trust measurement. Hollysys states compliance with the IEC 62443-3 framework.

Compatibility

Use only with the HOLLiAS MACS-K hardware, backplane, network and software release approved for K-CU11. Confirm controller redundancy pairing, firmware, project database, I/O count and network configuration before replacement.

Capacity values are controller limits from the Hollysys system specification; actual usable capacity depends on application load, control-cycle design and installed system configuration.

Applications

Large or medium process-control stations requiring redundant control and networks, up to 100 I/O modules, extensive point handling and PID control.

Suitable project contexts include energy, chemicals, process manufacturing and other DCS applications implemented on the supported HOLLiAS MACS-K platform.

FAQ

What is the official manufacturer? Hollysys.

How many I/O modules are supported? The official MACS-K specification lists up to 100 for K-CU11.

Does the controller support redundant networks? Yes. Hollysys lists both CNET and SNET redundancy, in addition to redundant controller configuration.

Recommended Models

The following models are provided for catalogue navigation. Confirm manufacturer, function and compatibility before ordering.

60-690-02 MTP RL 15HD EL5401D8011 MX-SM-N76 51453322-001 UDA ABB AX522 67C2820G32
D-67722, MX-SM-N160-PW CT 200 / 5 A DM 3258 71000082 ABB 6125/01-83-500 PD3120 PCS18
TR40 PT100/A/4 SB-3R-TC CX9000-A001 L220S PA2 TM171AETH
DDLEDC605GL LA9D50978 NVT Nv-226j-pv 1004UA03 DK-FLEXDK/CN3/CN5/CK3 871-238-012 ETH-02 HDL-MBUS01P.431 RJ45
LBB4440/00 ABB TA25DU-25 1SAZ211201R1051 DF143C 9251/02-40 AT-HDRX-IR + AT-HDTX-IR HDMI 500-034850

Product Enquiry

Manager: Leonia

Email: sales@mvme.cn

Phone: +86 18030175807

Technical content is based on publicly available manufacturer documentation. Verify the installed revision and project documentation before replacement or commissioning.

You May Also Like