HOLLiAS MACS-K main controller supporting redundant control, network resilience and large I/O capacity.
K-CU11 is a Hollysys main controller for the HOLLiAS MACS-K distributed control system. It is designed for field control stations within the MACS system architecture, coordinating control logic, I/O data and communication across the controller domain.
Hollysys documents redundant controller configuration together with redundancy for both the CNET control network and SNET system network.
| Manufacturer | Hollysys |
|---|---|
| Model | K-CU11 |
| System family | HOLLiAS MACS-K DCS |
| Controller role | Main controller module |
| CPU architecture | 32-bit PowerPC |
| Clock frequency | 400 MHz |
| Internal memory | 128 MB |
| Maximum I/O modules | 100 |
| Maximum I/O points | 3,200 |
| PID loop capacity | 300 |
| Redundancy | Controller, CNET and SNET redundancy supported |
| Integrity feature | ECC verification |
| Security processor | SM3 encryption algorithm processor |
Within the HOLLiAS architecture, management, system and control networks are separated into MNET, SNET and CNET layers. K-CU11 operates in the field control station layer and coordinates connected I/O modules through the system's controller and I/O-bus architecture.
The controller is based on the K-CU01 generation and adds an SM3 encryption processor plus expanded storage used for trusted boot and dynamic trust measurement. Hollysys states compliance with the IEC 62443-3 framework.
Use only with the HOLLiAS MACS-K hardware, backplane, network and software release approved for K-CU11. Confirm controller redundancy pairing, firmware, project database, I/O count and network configuration before replacement.
Capacity values are controller limits from the Hollysys system specification; actual usable capacity depends on application load, control-cycle design and installed system configuration.
Large or medium process-control stations requiring redundant control and networks, up to 100 I/O modules, extensive point handling and PID control.
Suitable project contexts include energy, chemicals, process manufacturing and other DCS applications implemented on the supported HOLLiAS MACS-K platform.
What is the official manufacturer? Hollysys.
How many I/O modules are supported? The official MACS-K specification lists up to 100 for K-CU11.
Does the controller support redundant networks? Yes. Hollysys lists both CNET and SNET redundancy, in addition to redundant controller configuration.
The following models are provided for catalogue navigation. Confirm manufacturer, function and compatibility before ordering.
| 60-690-02 MTP RL 15HD | EL5401D8011 | MX-SM-N76 | 51453322-001 UDA | ABB AX522 | 67C2820G32 |
| D-67722, MX-SM-N160-PW | CT 200 / 5 A DM 3258 | 71000082 | ABB 6125/01-83-500 | PD3120 | PCS18 |
| TR40 PT100/A/4 | SB-3R-TC | CX9000-A001 | L220S | PA2 | TM171AETH |
| DDLEDC605GL | LA9D50978 | NVT Nv-226j-pv | 1004UA03 DK-FLEXDK/CN3/CN5/CK3 871-238-012 | ETH-02 | HDL-MBUS01P.431 RJ45 |
| LBB4440/00 | ABB TA25DU-25 1SAZ211201R1051 | DF143C | 9251/02-40 | AT-HDRX-IR + AT-HDTX-IR HDMI | 500-034850 |
Manager: Leonia
Email: sales@mvme.cn
Phone: +86 18030175807
Technical content is based on publicly available manufacturer documentation. Verify the installed revision and project documentation before replacement or commissioning.