Warranty: 1 year
Condition : brand new in factory sealed box
Email: sales@mvme.cn
Chat online: +86 18030175807
A conformal-coated Safety Manager module for bringing discrete field states into safety-related control strategies.
Honeywell FC-SDI-1624 is a safe digital input module in the Safety Manager hardware family. Its role is to receive discrete field signals and present them to the safety system with the diagnostics and engineering discipline expected in safety-related applications.
The FC designation identifies the conformal-coated version. Selection should be made by exact model and released hardware revision, not by visual similarity to adjacent Safety Manager boards.
| Manufacturer | Honeywell |
|---|---|
| Model | FC-SDI-1624 |
| Product type | Safe digital input module |
| Safety platform | Honeywell Safety Manager |
| Input channels | 16 |
| Nominal input voltage | 24 VDC |
| Maximum input voltage | 36 VDC |
| Input current | 7 mA at 24 VDC |
| HIGH state | > 15 VDC |
| LOW state | < 9 VDC and input current < 2 mA |
| Input delay | Typically 10 ms |
| Module size | 4 TE, 3 HE (4 HP, 3U) |
| 5 VDC supply current | 8 mA |
| Internal 24 VDC supply current | 110 mA |
| External 24 VDC supply current | 110 mA |
| Approvals listed by Honeywell | CE, TÜV, UL, CSA and FM |
| Official released variants | 3432100 V1.0; 3432110 V1.1 |
| Coating | Conformal coated (FC prefix) |
Typical duties include emergency shutdown permissives, fire and gas status collection, trip contacts, machine-protection interlocks and other discrete signals assigned to a Safety Manager system.
The final application must follow the project safety requirements, approved cabinet design, field power concept and Honeywell Safety Manager documentation.
Honeywell release documentation identifies FC-SDI-1624 hardware variants under catalog entries 3432100 V1.0 and 3432110 V1.1. Exact revision, installed system release and project certification records should be checked before replacement.
For a spare or migration order, verify the board label, coating requirement and released Safety Manager configuration. A neighboring model number is not a substitute.
| No. | Model | No. | Model | No. | Model |
|---|---|---|---|---|---|
| 1 | M5004F1100 | 11 | YPP6000-6R0 | 21 | 837447005 M4-Power 737 839-001 G00 |
| 2 | BZME1-A25-BT | 12 | IC:AB444200035 | 22 | SF61B |
| 3 | 95A8994 | 13 | ABB DC551 / 1SAP220500R3001 CS31 | 23 | QUINT-DIODE/40 |
| 4 | ECINT1-1 730-802 RS232 RS485 | 14 | KFD2-UT2-EX1 | 24 | SMC-3 150-C9NB |
| 5 | MN-S3 | 15 | 6SA8252-0AC77 | 25 | DES-12-G 3PK-6500T |
| 6 | EM 3490 SS | 16 | 552854-506 | 26 | ABB 3BSE020838R1 DO840 |
| 7 | 1700130 | 17 | FP33 | 27 | 8323 / ID-NO.417727L |
| 8 | W7754T4431 | 18 | 5504GI | 28 | Rkc4.221t-30 |
| 9 | IC660BBD025 | 19 | 0004A3C138EA | 29 | GFW-VBC |
| 10 | DS7708-SR00004ZCWW | 20 | E3 1051.5/A004-9/1.0/4.5/8.7 | 30 | H4w4per2 |