Home>PLC>Horner APG HE693THM884N-45 High-Resolution Thermocouple Module

Hot Categories

Horner APG HE693THM884N-45 High-Resolution Thermocouple Module

Horner APG HE693THM884N-45 High-Resolution Thermocouple Module

Item NO.: 3814322

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameHorner APG HE693THM884N-45 High-Resolution Thermocouple Module
  • Item NO.3814322
  • Weight0.3400 kg = 0.7496 lb = 11.9931 oz
  • CategoryPLC
  • BrandGE General Electric
  • Creation Time2026-10-30
Series 90-30 Compatible Specialty I/OEight-Channel Thermocouple Input Module
8 TC CHANNELS · 0.1 °C RESOLUTION · J/K SENSOR SUPPORT

Horner APG HE693THM884N-45 High-Resolution Thermocouple Module

A high-resolution eight-channel thermocouple module execution for direct temperature-sensor connection and PLC alarm processing.

01
PRODUCT CONTEXT

Product Profile

HE693THM884N-45 belongs to Horner APG’s HE693THM884 high-resolution thermocouple module family. The module directly accepts J and K thermocouples and reports the selected engineering-unit format to the PLC I/O table.

The complete N-45 marking is retained as the procurement identity. Published HE693THM884 specifications govern the confirmed module functions, while the installed label and configuration bytes remain the source for the exact execution.

02
CONTROLLED DATA

Technical Data

Manufacturer

Horner APG

Exact model

HE693THM884N-45

Base family

HE693THM884

Thermocouple channels

8

Supported sensor types

J and K

Resolution

0.1 °C

Report increments

0.5 °C, 0.5 °F, 0.1 °C or 0.1 °F

PLC I/O allocation

8 %AI, 8 %AQ and 16 %I

Input impedance

Greater than 20 MΩ

Maximum sustained overload

±35 V

A/D conversion

18-bit integrating

Conversion time

5 ms

Scan rate

40 channels per second

Module power

100 mA at 5 V DC

Operating temperature

0 to 60 °C

03
OPERATING ROLE

System Role

01Direct thermocouple processing02Channel alarm resources03Selectable engineering units04Integrating conversion

Direct thermocouple processing

Performs the analog and digital processing needed to bring J or K sensor values into the PLC.

Channel alarm resources

Provides an open-circuit alarm and a configurable setpoint alarm for each input channel.

Selectable engineering units

Reports temperature in the documented Celsius or Fahrenheit increments selected in module configuration.

Integrating conversion

Uses high-resolution integrating conversion with strong common-mode rejection for industrial temperature signals.

04
SELECTION BOUNDARY

Compatibility

EXACT IDENTITY

HE693THM884N-45

Use the correct thermocouple extension alloy, preserve polarity and keep total wire resistance below the published limit.

HOST RECORD

Series 90-30 Compatible Specialty I/O

Retain the installed host, project and connection evidence that defines the approved use of this execution.

ACCEPTANCE

Verified field fit

Complete the model-specific checks described in the service sequence before return to operation.

05
FIELD USE

Applications

01

Multi-point temperature monitoring

Collecting eight J or K thermocouple measurements in a compatible PLC rack.

02

Equipment overtemperature alarms

Using the per-channel setpoint and open-circuit status in the application.

03

Thermal process service

Maintaining calibrated temperature loops with controlled extension wiring and grounding.

DocumentRecord sensor type, channel polarity, engineering units, alarm setpoints and module configuration bytes.WireUse matching extension wire, separate conduit and shielded twisted pair with the approved earth connection.TestApply known temperatures or a traceable simulator and verify scaling, alarms and open-circuit response.
06
CUSTOMER QUESTIONS

FAQ

Q01

What should accompany a HE693THM884N-45 enquiry?

Provide the complete N-45 label, PLC rack and slot, sensor type for each channel, configuration record and quantity.

Q02

Can a type N thermocouple be assumed from the N in HE693THM884N-45?

No. Horner’s published HE693THM884 channel support is J and K; the order-string character should not be used to invent a sensor type.

Q03

Why must unused inputs on HE693THM884N-45 be treated deliberately?

The manufacturer installation guidance calls for unused channels to be shorted to frame ground to support stable operation.

Q04

How should long thermocouple runs to HE693THM884N-45 be installed?

Use the correct extension alloy, keep total resistance below 100 Ω, route separately and apply the approved shield grounding.

Q05

What closes a HE693THM884N-45 commissioning record?

Retain channel-by-channel value checks, sensor-type confirmation, alarm tests and clean open-circuit diagnostics.

INDUSTRIAL SOURCING SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact records support a cleaner quotation

IndustryParts prepares HE693THM884N-45 enquiries around the complete manufacturer label, requested quantity and installed-system evidence. Share the application record that distinguishes this execution before a supply proposal is prepared.

Complete label retainedHost context reviewedQuantity linked to the enquiry
IndustryParts industrial parts support and order verification
ENQUIRY INFORMATION

Request a model-specific quotation

Send the complete HE693THM884N-45 label, requested quantity and delivery destination.

You May Also Like