RKC SBR-EX102 Two-Pen Industrial Chart Recorder
The two-pen execution in the SBR-EX100 recorder series for local process and temperature trend records.
Product Overview
SBR-EX102 is the two-pen model in the RKC SBR-EX100 recorder family. Each ordered instrument is defined by auxiliary codes covering the input assignment and by specified supply voltage and frequency.
The base model alone does not identify the input combination. The labels and full code must be read before replacing a DC voltage, thermocouple or RTD recording channel.
Performance
- Two independent pen positions allow simultaneous trend comparison on one chart.
- Input type is determined by the auxiliary code for each channel rather than by the SBR-EX102 base name.
- Supply voltage and 50 or 60 Hz frequency are specified when the recorder is ordered.
Technical Details
| Manufacturer | RKC Instrument |
|---|---|
| Documented Model | SBR-EX102 |
| Product Family | SBR-EX100 Series |
| Recording Format | Two-pen chart recorder |
| Input Classes | DC voltage / thermocouple or RTD, by auxiliary code |
| Supply Choices | 100, 115, 200 or 230 V AC, ordered execution |
| Frequency Choice | 50 or 60 Hz, ordered execution |
| Selection Basis | Complete auxiliary and option code |
System Integration
- Two verified field inputs
- Correct supply execution
- Chart media and pen consumables
Applications
- Process trend recording
- Two-channel temperature logging
- Batch documentation
FAQ
What does SBR-EX102 identify within the recorder family?
It identifies the two-pen execution; the one-pen and three-pen instruments use different model endings.
Does SBR-EX102 always use thermocouple inputs?
No. Channel input classes depend on the auxiliary code and can be ordered for DC voltage, thermocouple or RTD signals.
Can SBR-EX102 be replaced from the front-panel model alone?
No. Capture both channel codes, ranges, supply voltage, frequency and option code.
What consumables should be checked for SBR-EX102?
Confirm the correct chart paper, pen types and any printing consumables used by the installed recorder.
How should SBR-EX102 be tested after service?
Apply known values to both channels, verify scaling and pen separation, then confirm chart movement and timed printing.
What details are needed to quote SBR-EX102?
Send the full label, auxiliary codes, input ranges, supply, frequency, chart format and required accessories.
Recommended Models
| VPC210 | B110LP | MFD01 |
| KSM303500SP30 | HT9610P0100 | IN1606 |
| 5365EWP01 | Rkc4.221t-30 | HCW2GUS |
| S4-34895 | 8-2MBD | HFRC-01C |
| SEW WH37 CMP50S/BK/KY/AK0H/SB1 | NS-LXMM-A-400-20-2250-T2-N-AQ-L-NT1-RT | DSBC-40-50-PPSA-N3 |
| 6ES7137-6BD00-0BA0 | 3RV1041-4FA10 | FTW 913 K D3 |
| 8BAC0122.000-1 | BNS00A2 | 035 62 SCS |
| BF-50 | EV100 | 3IF672.9 |
| Legrand 574644 | LP-100S/4 S24V5 G830910 | ABB ACS607-0140-3 |
| FEX-40D-AMEU | 13I34-S20P2-T0D0-STBF10N-P0SU | 1071/7 |