  • Product NameSchneider Electric Triconex 3626X 32-Point SDO Module
  • Item NO.3794272
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandTriconex
  • Creation Time2026-10-14
TRICON CX | 24 VDC SDO | 32 POINT TMR

Schneider Electric Triconex 3626X 32-Point SDO Module

The commoned TMR supervised digital output module for 32 safety-related field circuits.

BrandSchneider Electric Triconex
Model3626X
Product TypeTricon CX Supervised Digital Output Module
01

Product Profile

3626X is the Tricon CX supervised digital output module. The official catalog identifies 32 commoned, supervised 24 VDC output points in a TMR architecture.

Correct field termination, common field power, load-supervision settings and the validated safety application remain part of the module boundary.

02

Technical Data

Manufacturer Schneider Electric Triconex
Exact Model 3626X
Platform Tricon CX
Product Type Supervised digital output module
Architecture Triple Modular Redundant (TMR)
Output Count 32 points
Nominal Field Voltage 24 VDC
Output Arrangement Supervised and commoned
Configuration TriStation 1131 project and load-supervision settings
03

System Role

01

Drives 32 documented safety-related discrete output circuits.

02

Uses TMR processing and output voting.

03

Supports field-load supervision with approved termination and settings.

04

Returns module and channel diagnostics to the safety application.

04

Compatibility

  • Match chassis, project release and supported field termination.
  • Confirm common field power, fusing and grounding for the output group.
  • Document load, inrush, suppression and supervision for every point.
  • Preserve project checksum and prove every affected output end to end.
05

Applications

  • Emergency shutdown solenoids and trip relays.
  • Fire-and-gas audible, visual or release circuits.
  • Burner management and process interlock outputs.
06

FAQ

01

What load information is needed for each 3626X channel?

Provide steady current, inrush, suppression, cable, voltage and supervision current.

02

Why is commoned field power important for 3626X?

Supply isolation and fusing affect the full 32-point group.

03

Can an older 16-point module replace 3626X?

No automatic substitution is valid; chassis, points, termination and logic differ.

04

What should be preserved before changing 3626X?

Save the project, checksum, assignments, settings, bypasses and proof-test baseline.

05

How should replacement 3626X be accepted?

Verify diagnostics and redundancy, then prove every affected final element.