Home>PLC>Siemens 6ES7 288-1CR20-0AA1,6ES7288-1CR20-0AA1 SIMATIC S7-200 SMART CPU CR20s

Hot Categories

Siemens 6ES7 288-1CR20-0AA1,6ES7288-1CR20-0AA1 SIMATIC S7-200 SMART CPU CR20s

Siemens 6ES7 288-1CR20-0AA1,6ES7288-1CR20-0AA1 SIMATIC S7-200 SMART CPU CR20s

Item NO.: 3403010

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6ES7 288-1CR20-0AA1,6ES7288-1CR20-0AA1 SIMATIC S7-200 SMART CPU CR20s
  • Item NO.3403010
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2025-10-13
S7-200 SMART | COMPACT SERIAL CPU | AC/DC/RELAY

Siemens 6ES7288-1CR20-0AA1 SIMATIC S7-200 SMART CPU CR20s

A compact serial CPU with 12 digital inputs, 8 relay outputs and 20 KB program and data memory.

ManufacturerSiemens
Exact model6ES7288-1CR20-0AA1
Product typeSIMATIC S7-200 SMART CPU CR20s
01

Product Identification

6ES7288-1CR20-0AA1 is the Siemens SIMATIC S7-200 SMART CPU CR20s. The compact serial CPU uses an 85 to 264 V AC supply, 12 onboard 24 V DC inputs and 8 relay outputs rated 2 A.

The CPU provides 20 KB of program and data memory and is engineered with STEP 7-Micro/WIN SMART. Its serial-oriented CR architecture must remain separate from SR and ST standard CPUs.

The complete 0AA1 article number identifies the exact CPU generation and prevents a visually similar controller from being selected without compatibility review.

02

Engineering Data

Manufacturer Siemens
Exact article number 6ES7288-1CR20-0AA1
Product family SIMATIC S7-200 SMART
CPU designation CPU CR20s
CPU category Compact serial CPU
CPU architecture AC/DC/relay
Supply voltage 85 to 264 V AC, 47 to 63 Hz
Digital inputs 12 onboard, 24 V DC
Digital outputs 8 onboard relay outputs, 2 A
Program and data memory 20 KB
Bit execution time 150 ns
Word execution time 1.2 µs
Floating-point execution time 3.6 µs
Engineering software STEP 7-Micro/WIN SMART
Article generation 0AA1
03

Functions

01

Executes compact S7-200 SMART control applications with twenty onboard digital points.

02

Switches field loads through eight onboard relay outputs.

03

Provides the CR-series serial communication architecture for compact controller systems.

04

Retains program and data in the documented 20 KB memory allocation.

04

Applications

  • Compact machine control requiring AC-powered relay-output architecture.
  • Serially connected S7-200 SMART systems engineered with Micro/WIN SMART.
  • Panel replacements where the original CR20s terminal and communication plan must be retained.
  • Small control stations requiring twelve inputs and eight relay outputs.
05

Lifecycle

  • Archive the Micro/WIN SMART project, password state, serial configuration and complete label before shutdown.
  • Verify AC supply, 24 V DC input commons, relay load ratings and contact suppression.
  • Do not assume an SR20 or ST20 provides the same communication, supply or output architecture.
  • After replacement, test every point, serial communications and the complete interlock sequence.

About IndustryParts

https://www.industryparts.com/

Compact serial CPU selection keeps supply and outputs explicit

IndustryParts handles 6ES7288-1CR20-0AA1 with its complete CR20s identity, serial configuration and relay-load record preserved.

  • CR20s identity retained
  • Serial settings requested
  • Relay architecture checked
IndustryParts engineering review
07

FAQ

Q01

Is 6ES7288-1CR20-0AA1 interchangeable with an ST20 CPU?

No direct substitution should be assumed. CR20s uses AC supply and relay outputs, while ST20 uses a DC/DC/DC architecture.

Q02

What should accompany a 6ES7288-1CR20-0AA1 enquiry?

Provide the complete CPU label, Micro/WIN SMART project, serial-network settings, terminal photographs and relay-load list.

Q03

Why must the CR20s serial architecture be recorded?

Communication interfaces and project settings are part of the installed controller path and can differ from standard SR or ST CPUs.

Q04

How should relay loads be reviewed before CPU exchange?

Document load voltage and current, inductive-load suppression, shared commons and the approved isolation plan for every affected output.

Q05

What acceptance checks are required after installation?

Verify the project, serial link, every digital input and relay output and all machine interlocks under controlled conditions.

Enquiry Information

Send the complete 6ES7288-1CR20-0AA1 label, quantity and destination for an exact enquiry record.

WHATSAPP / PHONE+86 18030175807

You May Also Like