Home>PLC>Siemens 6ES7222-1HH32-0XB0 SM 1222 SIMATIC S7-1200 Output Modules

Hot Categories

Siemens 6ES7222-1HH32-0XB0 SM 1222 SIMATIC S7-1200 Output Modules

Siemens 6ES7222-1HH32-0XB0 SM 1222 SIMATIC S7-1200 Output Modules

Item NO.: 3809416

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6ES7222-1HH32-0XB0 SM 1222 SIMATIC S7-1200 Output Modules
  • Item NO.3809416
  • Weight0.2200 kg = 0.4850 lb = 7.7603 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-10-26
Siemens SM 1222 SIMATIC S7-1200 Output Modules
SIMATIC S7-1200 SM 1222PRODUCT RECORD

SM 1222 RELAY OUTPUT · 16 CHANNELS · 2 A CONTACT RATING

Siemens SM 1222 SIMATIC S7-1200 Output Modules

Requested configuration: 6ES7222-1HH32-0XB0

The 16-relay execution of the SM 1222 family, identified by the complete order number 6ES7222-1HH32-0XB0.

Output form16 relay contacts
Load domainsAC or DC circuits
Protection boundaryExternal short-circuit protection
01
PRODUCT CONTEXT

Overview

6ES7222-1HH32-0XB0 is the 16-output relay version of the SIMATIC S7-1200 SM 1222 signal module. Each output is a mechanical relay contact intended for suitable AC or DC field loads. Siemens rates the contacts at up to 2 A for resistive or inductive service within the published limits.

This execution accepts a 24 VDC relay-coil supply from 20.4 to 28.8 VDC and draws up to 135 mA from the 5 V backplane bus. The module does not provide output short-circuit protection, so branch protection and load suppression remain part of the panel design.

02
CONTROLLED DATA

Specifications

Manufacturer
Siemens
Exact order number
6ES7222-1HH32-0XB0
Product designation
SM 1222, DQ 16x relay / 2 A
Digital outputs
16
Output grouping
One contact per group
Rated contact current
2 A
Permitted DC load voltage
5 to 30 VDC
Permitted AC load voltage
5 to 250 VAC
Maximum lamp load
30 W DC; 200 W AC
Maximum output delay
10 ms on; 10 ms off
Typical power loss
8.5 W
Backplane current
135 mA maximum at 5 VDC
Relay-coil supply
24 VDC nominal; 20.4 to 28.8 VDC
Short-circuit protection
External protection required
Mechanical life
Up to 10 million operations without load
Rated-load contact life
Up to 100,000 operations
03
FUNCTIONAL PROFILE

Features

A

Relay isolation for varied loads

Mechanical contacts let the module switch appropriate AC or DC circuits without forcing a transistor-output wiring scheme.

B

Sixteen-point density

A single SM 1222 adds sixteen commanded field outputs to an S7-1200 station.

C

Visible operating boundary

The contact rating, lamp-load limit and switching frequency can be documented directly against each connected load.

D

Serviceable project mapping

The point addresses remain tied to the STEP 7 hardware configuration and terminal schedule during replacement.

IndustryParts industrial automation support
INDUSTRIAL PARTS SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact identity before quotation

IndustryParts prepares 6ES7222-1HH32-0XB0 enquiries around the complete manufacturer label, requested quantity and destination. For controlled replacements, include the host-system record, field photographs and configuration evidence that apply to this exact execution.

Complete labelRevision retainedApplication evidence
04
FIELD USE

Applications

Machine auxiliaries

Switching contactors, pilot devices or interposing relays after the connected load has been checked against the contact limits.

Mixed-voltage panels

Separating approved AC and DC load groups through the documented terminal and protection arrangement.

S7-1200 expansion

Adding sixteen relay-command points where slower mechanical switching is suitable for the process.

05
SERVICE DISCIPLINE

Lifecycle

01

Before removal

Archive the STEP 7 hardware configuration and record all sixteen terminal assignments, commons, field voltages and external fuses.

02

During exchange

Isolate every load source, preserve suppression devices and install only after the complete 6ES7222-1HH32-0XB0 label is confirmed.

03

After energization

Command each point individually, check the connected device response and record contact, fuse and common-circuit results.

06
CUSTOMER QUESTIONS

FAQ

Q01

Can 6ES7222-1HH32-0XB0 drive a load without an external protective device?

No. Siemens specifies no onboard short-circuit protection, so the field circuit needs protection engineered for its conductor and connected load.

Q02

What should be reviewed before moving a load to 6ES7222-1HH32-0XB0?

Confirm AC or DC voltage, steady current, inrush, lamp wattage, inductive suppression and required switching frequency against the relay limits.

Q03

Is 6ES7222-1HH32-0XB0 interchangeable with a 16-point transistor SM 1222?

Not as a wiring-equivalent replacement. Relay and transistor outputs have different voltage, current, switching-speed, leakage and protection behavior.

Q04

Why should the STEP 7 project accompany an 6ES7222-1HH32-0XB0 enquiry?

The hardware catalog selection and channel addresses show how the sixteen outputs are assigned in the installed S7-1200 station.

Q05

What proves an 6ES7222-1HH32-0XB0 replacement is ready for service?

A point-by-point command test, correct load response, verified commons, intact protection and an updated terminal record provide the acceptance evidence.

ENQUIRY INFORMATION

Send the complete 6ES7222-1HH32-0XB0 label, requested quantity and destination.

You May Also Like