Home>PLC>Siemens 6ES7288-1SR30-0AA1 SIMATIC S7-200 SMART CPU SR30

Hot Categories

Siemens 6ES7288-1SR30-0AA1 SIMATIC S7-200 SMART CPU SR30

Siemens 6ES7288-1SR30-0AA1 SIMATIC S7-200 SMART CPU SR30

Item NO.: 3796501

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6ES7288-1SR30-0AA1 SIMATIC S7-200 SMART CPU SR30
  • Item NO.3796501
  • Weight0.4300 kg = 0.9480 lb = 15.1678 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-10-16
Standard controller / expanded integrated I/O

Siemens 6ES7288-1SR30-0AA1 SIMATIC S7-200 SMART CPU SR30

A standard S7-200 SMART CPU with eighteen 24 V DC inputs, twelve 2 A relay outputs, 30 KB combined program/data memory and onboard Ethernet plus RS485.

ManufacturerSiemens
Exact model6ES7288-1SR30-0AA1
Product typeCPU SR30 AC/DC/Relay
01

Technical Summary

Controller profile

6ES7288-1SR30-0AA1 is the CPU SR30 AC/DC/relay controller for SIMATIC S7-200 SMART systems. The 110 mm housing carries eighteen integrated digital inputs and twelve relay outputs for machine and panel applications.

The CPU is engineered in STEP 7 Micro/WIN SMART and provides one Industrial Ethernet interface, one RS485 interface, optional microSDHC support and PROFINET connectivity for up to eight IO devices.

Local inputs18 × 24 V DC
Local outputs12 × relay, 2 A
Memory30 KB program/data
Housing width110 mm
02

Specifications

Official product data
Manufacturer Siemens
Product family SIMATIC S7-200 SMART
Exact article number 6ES7288-1SR30-0AA1
CPU designation CPU SR30 AC/DC/Relay
Supply range 85–264 V AC, 47–63 Hz
Integrated digital inputs 18 × 24 V DC
Integrated digital outputs 12 × relay, 2 A
Program memory 18 KB
User data memory 12 KB
Optional memory card microSDHC
Communication interfaces 1 × Industrial Ethernet; 1 × RS485
PROFINET IO devices Up to 8 connectable devices
High-speed counters 6
I/O address area 144 bytes inputs; 144 bytes outputs
Real-time clock backup 7 days; hardware clock without battery backup
Power loss, maximum 14 W
Current consumption 72 mA at 240 V AC rated; maximum 136 mA at 120 V AC
Inrush current, maximum 8.9 A at 264 V
Backplane/EM bus output 5 V DC, maximum 1.4 A
Engineering software STEP 7 Micro/WIN SMART
Mounting standard Standard DIN rail
03

Features

Integrated capabilities
01

Expanded local I/O

Eighteen inputs and twelve 2 A relay outputs provide a larger onboard signal set than CPU SR20 while keeping the controller self-contained.

02

Network and serial access

The built-in Ethernet and RS485 interfaces support two distinct integration paths without consuming an expansion position.

03

Deterministic service data

The exact -0AA1 suffix, firmware version and project archive remain part of the replaceable-unit identity.

04

Maintenance media

Optional microSDHC support and a seven-day clock backup help preserve a controlled service and recovery process.

04

Compatibility

System fit
Engineering

Confirm that the approved STEP 7 Micro/WIN SMART release supports the installed CPU firmware.

PROFINET

Retain device names, IP configuration and the design limit of eight connectable IO devices.

RS485

Document protocol, baud rate, station address, termination and any converter used on the serial path.

Local wiring

Match the eighteen-input/twelve-output terminal map and verify each relay load before energization.

05

Replacement

Controlled exchange

Before removal

  • Capture the complete 6ES7288-1SR30-0AA1 nameplate, firmware version, project revision and communication settings.
  • Export the running STEP 7 Micro/WIN SMART project and record expansion modules, PROFINET devices and serial nodes.
  • Isolate the mains supply and all external voltages routed through the relay contacts.

Before restart

  • Confirm the 110 mm housing and the exact eighteen-input/twelve-output terminal assignment before reconnection.
  • Load only the validated project and verify clock, Ethernet, RS485, expansion I/O and every onboard point.
  • Treat a move to CPU SR20 or CPU SR40 as an engineering change rather than a catalog-number substitution.
06

FAQ

Customer checks
Q01What evidence is needed to identify 6ES7288-1SR30-0AA1 correctly?

Use the complete nameplate, firmware display or service record, project archive and photographs of the installed terminal wiring and expansion modules.

Q02Can 6ES7288-1SR30-0AA1 be exchanged for an older SR30 suffix automatically?

No. The same SR30 family name does not remove firmware, hardware-execution and project compatibility checks; validate the full article number before exchange.

Q03When should 6ES7288-1SR30-0AA1 be selected instead of SR20 or SR40?

Select by the validated local I/O count, memory requirement, enclosure width and project architecture—not by physical similarity or family name alone.

Q04What communication records should be preserved for 6ES7288-1SR30-0AA1?

Keep the Ethernet IP and device name, PROFINET topology, RS485 protocol settings, station addresses and cable-termination record.

Q05How should 6ES7288-1SR30-0AA1 be commissioned after replacement?

Restore the approved project, verify the firmware boundary, test all eighteen inputs and twelve relay outputs, then prove every networked device and affected safety function.

IndustryParts engineering review

About IndustryParts

https://www.industryparts.com/

The SR30 hardware, firmware and project are reviewed as one service record

IndustryParts prepares 6ES7288-1SR30-0AA1 enquiries with the exact CPU execution, installed communication paths and expansion context visible before quotation.

  • Full Siemens article number preserved
  • Firmware and project boundary recorded
  • PROFINET and RS485 context reviewed

Enquiry Information

Send the complete 6ES7288-1SR30-0AA1 label, quantity and destination for an exact enquiry record.

WHATSAPP / PHONE+86 18030175807

You May Also Like