Siemens 6ES7288-1ST60-0AA1 SIMATIC S7-200 SMART CPU ST60
A DC/DC/DC compact controller with 60 onboard digital channels, PROFINET, RS485 and an extended operating range.
Product Overview
6ES7288-1ST60-0AA1 is the AA1 revision of the SIMATIC S7-200 SMART CPU ST60. It integrates 36 digital inputs, 24 transistor outputs and 50 KB of combined program and data memory.
The CPU provides Ethernet/PROFINET and RS485 communication while extending the operating range below 0 °C compared with the earlier AA0 revision.
Performance
- Executes bit instructions in 150 ns, word instructions in 1.2 µs and floating-point instructions in 3.6 µs.
- Supports up to eight PROFINET IO devices in controller operation at the documented firmware level.
- Provides six high-speed counter inputs and three 100 kHz pulse outputs for fast machine signals.
- Runs up to eight PID control loops within the compact CPU platform.
- Operates from -20 to +60 °C when mounted horizontally, or -20 to +50 °C vertically.
Technical Details
| Manufacturer | Siemens |
|---|---|
| Article Number | 6ES7288-1ST60-0AA1 |
| Controller Family | SIMATIC S7-200 SMART |
| CPU Variant | ST60, DC/DC/DC |
| Rated Supply | 24 V DC |
| Permitted Supply Range | 20.4–28.8 V DC |
| Onboard Digital Inputs | 36 × 24 V DC |
| Onboard Digital Outputs | 24 × 24 V DC transistor |
| Program / Data Memory | 30 KB / 20 KB |
| Communication | 1 Ethernet/PROFINET and 1 RS485 |
| PROFINET Capacity | Up to 8 IO devices |
| Memory-Card Option | microSDHC |
| Maximum Input Current | 710 mA |
| Maximum Power Loss | 20 W |
| Protection | IP20 |
| Engineering Software | STEP 7 Micro/WIN SMART |
System Integration
- Use the complete AA1 hardware identifier when matching the Micro/WIN SMART project and replacement inventory.
- Assign PROFINET names and addresses consistently with the saved configuration before reconnecting distributed devices.
- Preserve the RS485 network parameters and termination arrangement when the serial port is in service.
- Check the high-speed counter and pulse-output mapping because those channels have application-specific wiring.
- Apply the temperature limit for the actual horizontal or vertical mounting orientation.
Applications
- Compact machines with a high onboard digital-channel count.
- Control panels exposed to sub-zero ambient temperatures within the AA1 operating range.
- PROFINET-connected skids that also retain an RS485 device network.
- Counting, pulse-output and PID applications maintained in STEP 7 Micro/WIN SMART.
FAQ
What does the 6ES7288-1ST60-0AA1 revision add to the ST60 selection?
Its documented operating range extends to -20 °C, with different upper limits for horizontal and vertical mounting.
How many onboard digital channels are included?
The CPU has 36 digital inputs and 24 transistor outputs.
When is PROFINET I-Device functionality available?
The function is supported from the documented V2.5 firmware level.
Can a relay-output ST60 replace the 6ES7288-1ST60-0AA1 directly?
No. This is a DC/DC/DC CPU with transistor outputs, so output technology and field wiring must match.
What project information should be saved before exchange?
Save the program, hardware revision, PROFINET configuration, RS485 settings and high-speed I/O allocation.
Does the same temperature ceiling apply in every orientation?
No. The horizontal and vertical mounting limits are different.
Recommended Models
| SR2 A201FU | N3532TA-ADBE-M | ALM-1 |
| QFA3160 | 0-073-0015-2 | HTXRC12A2 |
| IR.EX-P-0600 | SDV531-L33/PRP | PTM03-CD |
| RDR-80581AGU-NT2-20 | 400017 6DI | WGMXMBSS4 |
| GE 55-501463G002 | AI810 | POS-M1106 |
| ABB L0055994 GJR5251400R3202 | DDMC802-PB | LG9 |
| c-c500 500/MTP850,810Ex | 7kt0311 | K30/3 |
| T9600-TF21-1JS0 | 140012 | TETRA 4010 |
| C2IR-8 6500429 | 75314021 | TK_C21P |
| R9861500T01 | 7XV5650-0BA00/BB RS485-FO | ABB Q631 0064 R0111 |