Siemens 6ES7288-3AR04-0AA0 EM AR04 4-Channel RTD Input Module

Siemens 6ES7288-3AR04-0AA0 EM AR04 4-Channel RTD Input Module

Item NO.: 3475718

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6ES7288-3AR04-0AA0 EM AR04 4-Channel RTD Input Module
  • Item NO.3475718
  • Weight0.1800 kg = 0.3968 lb = 6.3493 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2025-12-04
FOUR RTD CHANNELS · 16-BIT CONVERSION · 2/3/4-WIRE SENSORS

Siemens 6ES7288-3AR04-0AA0 EM AR04 4-Channel RTD Input Module

A four-channel EM AR04 module for RTD temperature and resistance measurements in S7-200 SMART systems.

Channels4 RTD inputsConnection2-, 3- or 4-wireModule width45 mm

Product Profile

Siemens 6ES7288-3AR04-0AA0 is the SIMATIC S7-200 SMART EM AR04 expansion module with four 16-bit RTD input channels. It supports documented resistance-temperature sensors and resistance measurement through two-, three- or four-wire circuits.

The four-channel AR04 identity must not be confused with the two-channel AR02 or with the later G2 article suffix. The installed label and project channel map establish the exact spare boundary.

Internal calibration and diagnostics support controlled commissioning, including overflow, underflow, wire-break and low-supply recognition.

Technical Data

ManufacturerSiemens
Exact model6ES7288-3AR04-0AA0
Product designationEM AR04
Input count4
Measurement typeRTD and resistance
Resolution16-bit conversion
Sensor wiring2-, 3- or 4-wire
Temperature data resolution0.1 °C or 0.1 °F
Resistance data resolution15 bits plus sign
Input impedanceAt least 10 MΩ
Noise rejection85 dB normal mode; more than 120 dB common mode
Channel-to-channel isolationNone
Field-to-logic isolation500 V AC
Maximum cable length100 m to the sensor
Power loss1.5 W
24 V DC current40 mA
SM bus current80 mA
ConnectorsGold-plated

System Role

SOURCESIMATIC S7-200 SMART
→
CONTROLLED ITEM6ES7288-3AR04-0AA0
→
FIELD RESULTMachine thermal monitoring

Compatibility

CHECKPOINT

Channel record

Archive four sensor types, ranges, lead arrangements, units, limits and terminal assignments.

CHECKPOINT

Installation audit

Check 24 V supply, shields, maximum cable run and the exact four-channel label.

CHECKPOINT

Reference verification

After calibration, test every channel with a traceable resistance or temperature reference.

Applications

APPLICATION

Machine thermal monitoring

Four bearing, winding or enclosure temperature points in one S7-200 SMART station.

APPLICATION

Process RTD acquisition

Four documented sensor circuits with engineering units and alarm limits retained.

APPLICATION

AR04 service exchange

Like-for-like replacement with all channel types, lead arrangements and scaling preserved.

IndustryParts team supporting industrial automation orders
INDUSTRIAL AUTOMATION SUPPLY SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact-model handling for 6ES7288-3AR04-0AA0

IndustryParts prepares this em ar04 4-channel rtd input module enquiry with the complete label, requested quantity and installed-system evidence kept together, so the proposed supply can be compared with the actual application before dispatch.

Hardware revision kept visible
Configuration boundary documented
Shipment record linked to the enquiry

FAQ

Q01Can 6ES7288-3AR04-0AA0 use the two-channel AR02 project map?

No. 6ES7288-3AR04-0AA0 has four inputs, so hardware identity, addressing and channel configuration must follow AR04 records.

Q02What distinguishes 6ES7288-3AR04-0AA0 from a G2 AR04 article?

The complete suffix is different. Do not treat 0AA0 and a later G2 suffix as interchangeable without Siemens compatibility evidence.

Q03What wiring evidence should accompany 6ES7288-3AR04-0AA0?

Provide all four sensor types, two-/three-/four-wire diagrams, shield practice, cable lengths, ranges and terminal photographs.

Q04How should wire-break behavior be checked on 6ES7288-3AR04-0AA0?

Use the approved controlled test for each configured channel and confirm the expected diagnostic and process fallback response.

Q05What belongs in the 6ES7288-3AR04-0AA0 acceptance report?

Record startup calibration completion, four reference results, units, alarm limits, diagnostic tests, 24 V supply and final project identity.