Home>PLC>Siemens 6ES7288-3AT04-0AA0 EM AT04 Thermocouple Input Module

Hot Categories

Siemens 6ES7288-3AT04-0AA0 EM AT04 Thermocouple Input Module

Siemens 6ES7288-3AT04-0AA0 EM AT04 Thermocouple Input Module

Item NO.: 3403032

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6ES7288-3AT04-0AA0 EM AT04 Thermocouple Input Module
  • Item NO.3403032
  • Weight0.1200 kg = 0.2646 lb = 4.2329 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2025-10-13
4 THERMOCOUPLE INPUTS · 16-BIT CONVERSION · COLD-JUNCTION COMPENSATION

Siemens 6ES7288-3AT04-0AA0 EM AT04 Thermocouple Input Module

A four-channel S7-200 SMART thermocouple input module for documented temperature measurement points.

MANUFACTURERSiemensPRODUCT FAMILYSIMATIC S7-200 SMARTPRODUCT TYPEEM AT04 Thermocouple Input Module
SYSTEM RECORD

Product Identification

01

Siemens 6ES7288-3AT04-0AA0 is the SIMATIC S7-200 SMART EM AT04 module with four 16-bit thermocouple inputs. Temperature values are represented with 0.1 °C or 0.1 °F resolution.

Published module data includes at least 10 MΩ input impedance, 500 V AC field-to-logic isolation for one minute, ±0.05% full-scale repeatability and cold-junction error within ±1.5 °C.

Thermocouple type, units, open-wire response, filter choice, polarity and compensation arrangement must be retained per channel. Unused channels should be deactivated or treated exactly as the Siemens manual specifies.

SYSTEM RECORD

Engineering Data

02
ManufacturerSiemens
Exact model6ES7288-3AT04-0AA0
Product designationEM AT04
Input count4 thermocouple channels
Conversion16 bit
Temperature resolution0.1 °C or 0.1 °F
Voltage resolution15 bits plus sign
Input impedanceAt least 10 MΩ
Repeatability±0.05% of full scale
Cold-junction error±1.5 °C
Isolation test500 V AC field-to-logic for 1 minute
Maximum sensor cable100 m
Power loss1.5 W
SM bus current80 mA
24 V DC current40 mA
SYSTEM RECORD

Functions

03
A

Temperature acquisition

Converts four thermocouple millivolt signals into configured temperature values.

B

Junction compensation

Uses the module terminal condition to compensate the thermocouple reference junction.

C

Diagnostic handling

Reports configured range and wire-break conditions to the S7-200 SMART project.

INDUSTRIAL AUTOMATION SUPPLY SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact-model handling for 6ES7288-3AT04-0AA0

IndustryParts keeps the complete 6ES7288-3AT04-0AA0 identity, requested quantity and installed-system evidence together so the proposed supply can be checked against the actual application before dispatch.

Hardware suffix kept visible
Configuration boundary documented
Delivery record linked to the exact enquiry
IndustryParts industrial automation support team
SYSTEM RECORD

Applications

04
APPLICATION

Machine temperature

Monitors heaters, tooling or bearings through documented thermocouple types.

APPLICATION

Process skid

Collects four temperature points in a compact S7-200 SMART control station.

APPLICATION

Service replacement

Restores an EM AT04 position while retaining sensor, units and compensation records.

SYSTEM RECORD

Lifecycle

05

Document

Keep sensor type, units, limits, cable material and compensation settings per channel.

Inspect

Check polarity, terminal condition, shielding and extension-wire continuity.

Verify

Run traceable multi-point tests and confirm wire-break and alarm behavior.

SYSTEM RECORD

FAQ

07
Q01How many thermocouples can 6ES7288-3AT04-0AA0 accept?

6ES7288-3AT04-0AA0 provides four thermocouple input channels.

Q02What sensor information should accompany 6ES7288-3AT04-0AA0?

Provide thermocouple type, polarity, channel number, extension-wire material, units, filter and alarm limits for every point.

Q03How should unused 6ES7288-3AT04-0AA0 channels be handled?

Deactivate them in the approved configuration or follow the Siemens shorting practice; do not leave their diagnostic behavior undefined.

Q04Why does terminal condition matter for 6ES7288-3AT04-0AA0?

Cold-junction compensation depends on the module terminal environment, so terminal integrity and temperature gradients can affect the reading.

Q05What acceptance test is appropriate for 6ES7288-3AT04-0AA0?

Apply traceable references to all four channels and record temperature accuracy, polarity, stability, open-wire response and alarm operation.