Home>PLC>Siemens 6ES7288-5CM01-0AA0 SB CM01 RS485/RS232 Communication Signal Board

Hot Categories

Siemens 6ES7288-5CM01-0AA0 SB CM01 RS485/RS232 Communication Signal Board

Siemens 6ES7288-5CM01-0AA0 SB CM01 RS485/RS232 Communication Signal Board

Item NO.: 3402242

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6ES7288-5CM01-0AA0 SB CM01 RS485/RS232 Communication Signal Board
  • Item NO.3402242
  • Weight18.0000 kg = 39.6832 lb = 634.9313 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2025-10-13
RS485 / RS232 · FREEPORT SUPPORT · COMPACT SIGNAL BOARD

Siemens 6ES7288-5CM01-0AA0 SB CM01 RS485/RS232 Communication Signal Board

A communication signal board adding one configurable serial interface to a compatible S7-200 SMART CPU.

MANUFACTURERSiemensPRODUCT FAMILYSIMATIC S7-200 SMARTPRODUCT TYPESB CM01 RS485/RS232 Communication Signal Board
SYSTEM RECORD

Product Identification

01

Siemens 6ES7288-5CM01-0AA0 is the SIMATIC S7-200 SMART SB CM01 communication signal board. It provides an RS485/RS232 interface for supported communication tasks, including Freeport operation.

Terminal X20 provides functional earth, Tx/B, RTS, M, Rx/A and a 5 V bias connection. The chosen electrical standard, pinout, baud rate, framing and protocol must match the connected device.

The board measures 35 × 52.2 × 16 mm, weighs 18.2 g and draws 50 mA from the 5 V supply. It must be selected and configured for a CPU that supports the CM01 signal-board position.

SYSTEM RECORD

Engineering Data

02
ManufacturerSiemens
Exact model6ES7288-5CM01-0AA0
Product designationSB CM01
InterfaceRS485/RS232
Supported communication modeFreeport
Terminal blockX20
X20 signalsFunctional earth, Tx/B, RTS, M, Rx/A, 5 V bias
Power loss0.5 W
5 V current50 mA
SYSTEM RECORD

Functions

03
A

Serial physical layer

Provides the configured RS485 or RS232 electrical interface.

B

Freeport messaging

Supports program-controlled serial frames under the approved communication logic.

C

Device integration

Connects documented instruments, drives or other serial devices to the S7-200 SMART CPU.

INDUSTRIAL AUTOMATION SUPPLY SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact-model handling for 6ES7288-5CM01-0AA0

IndustryParts keeps the complete 6ES7288-5CM01-0AA0 identity, requested quantity and installed-system evidence together so the proposed supply can be checked against the actual application before dispatch.

Hardware suffix kept visible
Configuration boundary documented
Delivery record linked to the exact enquiry
IndustryParts industrial automation support team
SYSTEM RECORD

Applications

04
APPLICATION

Instrument link

Connects a compatible serial instrument through documented framing and wiring.

APPLICATION

Legacy device interface

Adds RS232 or RS485 communication where an installed device cannot use Ethernet.

APPLICATION

Custom protocol task

Supports Freeport telegram handling implemented in the controlled CPU project.

SYSTEM RECORD

Lifecycle

05

Record

Keep port standard, pinout, cable, shield, termination, baud and framing settings.

Inspect

Check earth, reference conductor, polarity, termination and connector retention.

Validate

Record successful messages, timeouts, error handling and recovery after service.

SYSTEM RECORD

FAQ

07
Q01Which serial standards does 6ES7288-5CM01-0AA0 support?

6ES7288-5CM01-0AA0 supports an RS485 or RS232 communication interface when wired and configured for the selected standard.

Q02What X20 wiring data should accompany 6ES7288-5CM01-0AA0?

Provide conductor-by-conductor assignments for functional earth, Tx/B, RTS, M, Rx/A and any 5 V bias use.

Q03Can 6ES7288-5CM01-0AA0 communicate without project configuration?

No. Electrical wiring alone is insufficient; port parameters, protocol or Freeport logic and message timing must match the connected device.

Q04What causes common 6ES7288-5CM01-0AA0 replacement faults?

Reversed RS485 polarity, missing common reference, incorrect termination or bias, wrong RS232 pinout, mismatched baud or framing and lost Freeport logic are common causes.

Q05How should 6ES7288-5CM01-0AA0 be accepted?

Record bidirectional messages with the real device, verify error and timeout handling, and prove communication recovers after a controlled power cycle.

You May Also Like