Siemens 6ES7414-4HM14-0AB0 SIMATIC S7-400H CPU 414-4H
01Product Profile
Siemens 6ES7414-4HM14-0AB0 is a CPU 414-4H for high-availability SIMATIC S7-400H systems and appropriately engineered S7 F/FH applications. Official S7-400 compatibility and safety documentation identifies this hardware generation with firmware V4.5 and 1.4 MB each of program and data memory. In an H system the CPU works as one side of a synchronized controller pair, so the partner CPU, synchronization modules, firmware, rack layout, communications processors and project must be treated as one controlled configuration.
02Technical Data
| Manufacturer | Siemens |
|---|---|
| Article Number | 6ES7414-4HM14-0AB0 |
| Product Designation | CPU 414-4H |
| Automation System | SIMATIC S7-400H / engineered S7 F/FH |
| CPU Role | High-availability H-system CPU |
| Firmware Generation | V4.5.x |
| Program Memory | 1.4 MB |
| Data Memory | 1.4 MB |
| Total Work Memory | 2.8 MB |
| Redundancy Coupling | H-system synchronization modules required |
| PROFIsafe Support | V2 mode supported from the documented firmware generation |
| Engineering Requirement | Exact STEP 7, H-system and F-system compatibility required |
| Commercial Position | Legacy generation; confirm service availability |
03System Role
Controller Function
- Operates as one synchronized controller within a redundant S7-400H system.
- Supports bumpless or controlled H-system operation only when the complete partner, synchronization and project design is correct.
- Coordinates central and distributed I/O through the configured S7-400H communication architecture.
- Can host fail-safe runtime functions in a properly licensed and validated S7 F/FH system.
- Preserves the high-availability state, diagnostic history and switchover logic defined by the engineering project.
Key Capabilities
- High-availability CPU architecture supports synchronized operation in an S7-400H pair.
- Separate 1.4 MB program and 1.4 MB data areas provide 2.8 MB total work memory.
- Firmware V4.5 compatibility is documented for the exact CPU article in official S7-400 records.
- The CPU can participate in an S7 F/FH system when all required safety components and engineering rules are applied.
- PROFIsafe V2 mode is supported from the documented firmware generation.
- Supported S7-400 communications processors must be selected from the exact CPU and firmware compatibility combination.
04Compatibility
- Pair the CPU only with the documented compatible partner hardware, firmware and synchronization-module arrangement.
- Verify STEP 7, H-system option software and any S7 F Systems version before loading the project.
- Check every installed Industrial Ethernet and PROFIBUS communications processor against Siemens CPU compatibility lists.
- Preserve rack positions, redundant network paths, H parameters, memory-card data and process-image assignments.
- For F/FH use, verify PROFIsafe versions, F-I/O, safety signatures, F-monitoring times and acceptance records.
- Do not replace this generation with a newer H CPU without an engineered hardware, firmware, network and project migration.
05Applications
- Maintenance of legacy S7-400H redundant control systems.
- High-availability process plants using paired CPU 414-4H controllers.
- Engineered S7 F/FH applications with documented safety configuration and acceptance.
- Spare-part exchange where both H partners and synchronization hardware can be matched.
- Lifecycle assessments that must preserve installed communications processors and network paths.
- Controlled modernization projects requiring a complete backup of the H-system project and diagnostic configuration.
06FAQ
What is Siemens 6ES7414-4HM14-0AB0?
It is a legacy SIMATIC S7-400H CPU 414-4H used as one controller in a synchronized high-availability system.
How much work memory is documented?
Official S7 F/FH documentation identifies 1.4 MB for the program and 1.4 MB for data, for 2.8 MB total.
Can the CPU run by itself?
Commissioning and service modes are project-dependent, but its intended system role is as part of an engineered redundant S7-400H pair.
Can it be used in fail-safe applications?
It can be used in a properly engineered S7 F/FH system with the required software, licenses, F-I/O, safety configuration and validation.
Can a newer H CPU replace it directly?
No automatic replacement is assumed. Partner hardware, synchronization, firmware, networks, memory and the complete project require migration engineering.
What must be tested after replacement?
Test H synchronization, redundancy switchover, every network and I/O path, diagnostics, process continuity and all required functional-safety acceptance functions.
+Recommended Models
| G3439 6470 800 | 253-TALW-LAHG-C5-BD | LT-800-072 |
| 102044-00-48-15-02 060-987-166 | HD2-DM-B | ONS-C106XQ5 |
| EY-IO551F001 | ABE7H16R21 | CAMIR-8EZ |
| EC2895 | OM40BHOND | L4402N |
| 4930275 | GE RL4R RL4RA022T5 | TXB1.PBUS |
| 102097-00 | 719-DC-RC | 000518-003 NH30-200 PPM TXL-NH3 |
| ATSU01N222LT | VAZ-2FK-G10-BRIDGE | W28102J022A |
| CJS20W | GE IC693MDL940F | ABB TA25DU 1SAZ211201R1025 |
| 6ES5460-4UA13 | MPSR2-SHTW-GE | MWG2412 |
| GT-VBC | 4825882-C-000 | NFPW444-11/S2 |