  • SIMATIC S7-400 CPU 416F-2 DP fail-safe central processing unit
Siemens 6ES7416-2FN05-0AB0 SIMATIC S7-400 CPU 416F-2 DP

Siemens 6ES7416-2FN05-0AB0 SIMATIC S7-400 CPU 416F-2 DP

ManufacturerSiemensModel6ES7416-2FN05-0AB0Product TypeSIMATIC S7-400 CPU 416F-2 DP fail-safe central processing unit

01Key Information

Siemens 6ES7416-2FN05-0AB0 is the fail-safe CPU 416F-2 DP for SIMATIC S7-400 safety-related automation. It provides 5.6 MB of work memory, divided into 2.8 MB for the program and 2.8 MB for data, and combines MPI/PROFIBUS DP communication with a second PROFIBUS DP interface. Safety operation depends on the complete S7 F-system project, licensed engineering environment, compatible F-I/O, PROFIsafe parameters and documented acceptance procedure.

Selection ControlVerify the complete article number, hardware revision, firmware, memory, interfaces, engineering software and system architecture before ordering.

02Functions

Core Functions

  • Executes standard and fail-safe program sections in an approved SIMATIC S7 F-system configuration.
  • Provides 2.8 MB of program memory and 2.8 MB of data memory for the documented CPU generation.
  • Supports MPI and PROFIBUS DP communication for programming, HMI, controller and distributed-I/O functions.
  • Provides a second integrated PROFIBUS DP path for the engineered fieldbus architecture.
  • Supports S7 routing and compatible S7-400 Ethernet or PROFIBUS communication processors according to Siemens compatibility records.
  • Processes F-I/O diagnostics and configured safety reactions only within the validated safety application.

Product Identity

  • Manufacturer: Siemens
  • Model: 6ES7416-2FN05-0AB0
  • Product Type: SIMATIC S7-400 CPU 416F-2 DP fail-safe central processing unit
  • Status: Legacy fail-safe CPU generation; service availability confirmation required

03Specifications

Manufacturer Siemens
Article Number 6ES7416-2FN05-0AB0
Product Designation CPU 416F-2 DP
Automation System SIMATIC S7-400
CPU Type Fail-safe central processing unit
Firmware Generation V5.0 to V5.3 documented in Siemens compatibility records
Work Memory 5.6 MB total
Program Memory 2.8 MB
Data Memory 2.8 MB
Integrated Communication MPI / PROFIBUS DP plus second PROFIBUS DP interface
Safety Engineering SIMATIC S7 F-system workflow required
Communication Compatibility Firmware-specific S7-400 CP combinations
Commercial Position Legacy generation; confirm current Siemens service availability

04Installation

  • Match the complete article number, hardware revision and installed firmware before exchange.
  • Use a supported STEP 7 and safety-engineering release for the exact CPU and existing project.
  • Back up the standard and safety projects, F-signature, PROFIsafe addresses, F-monitoring times and acceptance records.
  • Document MPI and both PROFIBUS networks, including addresses, transmission rates, termination and every configured slave.
  • Check every communication processor against the exact CPU and firmware compatibility combination.
  • After installation, perform the prescribed safety acceptance tests and verify all standard and F-I/O reactions before returning the system to service.

05Lifecycle

  • This article belongs to an earlier S7-400 fail-safe CPU generation; current Siemens service and spare-part availability must be confirmed for each requirement.
  • Do not replace it with a standard CPU 416-2 because the standard variant does not provide the same fail-safe system role.
  • A newer F-CPU is not an automatic drop-in replacement; memory, firmware, fieldbus behavior, safety project and certification records require migration engineering.
  • Retain the original memory card and project only when their exact compatibility and data integrity are confirmed.
  • Preserve the complete safety validation package through repair, replacement or modernization.