Siemens 6ES7513-1AL02-0AB0 SIMATIC S7-1500 CPU 1513-1 PN
A spare-part CPU with 300 KB program memory, 1.5 MB data memory and one PROFINET IRT interface with an integrated two-port switch.
Key Information
6ES7513-1AL02-0AB0 is the CPU 1513-1 PN execution in the SIMATIC S7-1500 family. Siemens identifies a 40 ns bit performance and requires a SIMATIC Memory Card.
The first interface is PROFINET IRT with an integrated two-port switch. This article is listed as a spare part and Siemens names 6ES7513-1AM03-0AB0 as the successor.
A replacement review should preserve the installed firmware, project version, communication names, IP parameters, module order and memory-card record rather than relying on the CPU family name alone.
Functions
Execute the control program
Runs the loaded S7-1500 automation program with separate integrated program and data work memory.
Coordinate PROFINET I/O
Uses the integrated PROFINET IRT interface and two-port switch for the approved network topology.
Maintain diagnostics
Provides controller and network diagnostics through the S7-1500 engineering environment.
Retain project identity
Keeps the hardware catalog article, firmware and engineering project aligned during service.
Specifications
| Manufacturer | Siemens | Exact model | 6ES7513-1AL02-0AB0 |
|---|---|---|---|
| Product designation | CPU 1513-1 PN | Program work memory | 300 KB |
| Data work memory | 1.5 MB | Bit performance | 40 ns |
| Primary interface | PROFINET IRT with two-port switch | Memory card | SIMATIC Memory Card required |
| Lifecycle | Spare part | Published successor | 6ES7513-1AM03-0AB0 |
Installation
Archive
Back up the TIA Portal project and record firmware, device name, IP settings, rack order and memory-card data.
Match
Confirm the full article number and the supported engineering release before exchanging the CPU.
Restore
Insert the approved memory card, download the validated project and restore the recorded network identity.
Prove
Verify every I/O station, communication path, retained value, time setting and machine interlock.
Lifecycle
- Installed record
- Keep the full article number, firmware, memory-card identity and project checksum together.
- Successor boundary
- Treat the newer CPU as a migration decision, not as an automatic drop-in substitution.
- Acceptance evidence
- Store the download record, network diagnostics and functional-test results with the maintenance order.
FAQ
Q01What project evidence should accompany a 6ES7513-1AL02-0AB0 enquiry?+
Provide the archived TIA Portal project, CPU firmware, SIMATIC Memory Card record, device name, IP parameters and complete rack order.
Q02Can 6ES7513-1AM03-0AB0 replace 6ES7513-1AL02-0AB0 without engineering review?+
No. Siemens publishes it as the successor, but firmware, engineering version, communication behavior and project compatibility still require validation.
Q03Does 6ES7513-1AL02-0AB0 include internal program storage without a memory card?+
Siemens specifies that a SIMATIC Memory Card is required for this CPU.
Q04What network details should be captured before removing 6ES7513-1AL02-0AB0?+
Record the PROFINET device name, IP settings, port topology, IRT configuration and every connected I/O station.
Q05What proves 6ES7513-1AL02-0AB0 is ready after replacement?+
A controlled download, clean diagnostics, reachable I/O, verified communications and completed interlock tests close the service record.
About IndustryParts
https://www.industryparts.com/Spare CPU identity remains tied to the engineering archive
IndustryParts keeps the exact CPU article, project evidence, firmware record and requested quantity together before preparing a quotation.
- •Exact submitted model retained
- •Installed-system evidence reviewed
- •Requested quantity linked to the enquiry
Related Models
Request a model-specific quotation
Send the complete 6ES7513-1AL02-0AB0 label, requested quantity, delivery destination and installed-system context.