Integrated safety processing
Executes approved fail-safe logic together with the standard automation program.
Warranty: 1 year
Condition : brand new in factory sealed box
Email: sales@mvme.cn
Chat online: +86 18030175807
A fail-safe S7-1500 CPU with PROFINET IRT, PROFINET RT and PROFIBUS connectivity for safety and standard automation tasks.
6ES7516-3FN02-0AB0 is the CPU 1516F-3 PN/DP in the SIMATIC S7-1500F controller family. Its interface set combines one PROFINET IRT connection with a two-port switch, a second PROFINET RT interface and a PROFIBUS DP interface.
Siemens identifies 1.5 MB of program work memory, 5 MB of data work memory and 10 ns bit performance for this execution. A SIMATIC Memory Card is required, while the safety program and the standard program remain part of the same controlled project record.
Siemens
6ES7516-3FN02-0AB0
CPU 1516F-3 PN/DP
SIMATIC S7-1500F
1.5 MB
5 MB
PROFINET IRT with two-port switch
PROFINET RT
PROFIBUS DP
10 ns
SIMATIC Memory Card required
Fail-safe and standard control
Executes approved fail-safe logic together with the standard automation program.
Separates or combines PROFINET IRT, PROFINET RT and PROFIBUS communication according to the engineered plant topology.
Makes controller, network and safety diagnostics available within the S7-1500 engineering environment.
Links hardware, firmware, memory card content and the safety signature as one replacement record.
Running safety and standard sequences in a documented S7-1500F installation.
Connecting current PROFINET devices while retaining an engineered PROFIBUS segment.
Preserving project, firmware and safety validation evidence during planned CPU service.
Save the complete project, safety signature, firmware level, memory-card record, interface settings and 6ES7516-3FN02-0AB0 label.
Use the approved Siemens F-system procedure and retain every configured network identity and safety parameter.
Complete hardware diagnostics, communication checks and the authorized safety-function proof test before production.
Provide the full article label, firmware level, project version, safety signature, memory-card size, network topology and requested quantity.
No. A standard CPU does not provide the fail-safe execution and cannot be substituted for the F-CPU without a redesigned and approved safety concept.
The card participates in project loading and device restoration; its content and capacity must agree with the approved controller project.
Firmware, TIA Portal version, safety program signature and the configured PROFINET/PROFIBUS interfaces must remain mutually compatible.
Normal diagnostics, restored communications, a matching safety signature and completion of every authorized safety proof test are required.
IndustryParts prepares 6ES7516-3FN02-0AB0 enquiries around the complete manufacturer label, requested quantity and installed-system evidence. Share the application record that distinguishes this execution before a supply proposal is prepared.
Send the complete 6ES7516-3FN02-0AB0 label, requested quantity and delivery destination.