Home>PLC>Siemens 6ES7518-4FP00-0AB0 SIMATIC S7-1500F CPU 1518F-4 PN/DP

Hot Categories

Siemens 6ES7518-4FP00-0AB0 SIMATIC S7-1500F CPU 1518F-4 PN/DP

Siemens 6ES7518-4FP00-0AB0 SIMATIC S7-1500F CPU 1518F-4 PN/DP

Item NO.: 3817223

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6ES7518-4FP00-0AB0 SIMATIC S7-1500F CPU 1518F-4 PN/DP
  • Item NO.3817223
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-11-02
SIMATIC S7-1500FHigh-Performance Fail-Safe CPU
CPU 1518F-4 PN/DP · FOUR INTERFACES · 1 NS BIT PERFORMANCE

Siemens 6ES7518-4FP00-0AB0 SIMATIC S7-1500F CPU 1518F-4 PN/DP

A high-performance fail-safe S7-1500 CPU with extensive work memory and separate PROFINET plus PROFIBUS communication resources.

01
PRODUCT CONTEXT

Product Profile

6ES7518-4FP00-0AB0 is the CPU 1518F-4 PN/DP for high-performance fail-safe and standard control. The four-interface arrangement comprises PROFINET IRT with a two-port switch, PROFINET RT, PROFINET basic services and PROFIBUS.

The current Siemens product overview identifies 9 MB program work memory, 60 MB data work memory and 1 ns bit performance. Unlike the 1AC0 MFP bundle, this 0AB0 article should be controlled as its own CPU execution and software entitlement.

02
CONTROLLED DATA

Technical Data

Manufacturer

Siemens

Exact model

6ES7518-4FP00-0AB0

Product designation

CPU 1518F-4 PN/DP

Controller class

Fail-safe S7-1500F CPU

Program work memory

9 MB

Data work memory

60 MB

Interface 1

PROFINET IRT with two-port switch

Interface 2

PROFINET RT

Interface 3

PROFINET basic services

Interface 4

PROFIBUS

Bit performance

1 ns

Memory card

SIMATIC Memory Card required

03
OPERATING ROLE

System Role

01High-speed safety processing02Separated Ethernet roles03PROFIBUS integration04Large work-memory allocation

High-speed safety processing

Supports demanding fail-safe and standard applications with 1 ns bit performance.

Separated Ethernet roles

Provides distinct IRT, RT and basic-service interfaces for structured plant networking.

PROFIBUS integration

Retains a dedicated path for engineered DP devices.

Large work-memory allocation

Provides substantial program and data memory for complex controller projects.

04
SELECTION BOUNDARY

Compatibility

EXACT IDENTITY

6ES7518-4FP00-0AB0

6ES7518-4FP00-0AB0 must be selected from its exact article, firmware, project and safety signature.

HOST RECORD

SIMATIC S7-1500F

Retain the installed host, project and connection evidence that defines the approved use of this execution.

ACCEPTANCE

Verified field fit

Complete the model-specific checks described in the service sequence before return to operation.

05
FIELD USE

Applications

01

Large fail-safe production systems

Running extensive safety and standard logic in one controller asset.

02

Multi-network controller nodes

Separating deterministic I/O, plant Ethernet services and PROFIBUS traffic.

03

Controlled F-CPU replacement

Restoring a high-performance controller without changing the approved safety signature.

FreezeArchive the safety and standard projects, firmware, signature, memory card, certificates and every interface identity.RestoreApply the Siemens F-system replacement process and load only the approved controller project.ProveCheck all networks, diagnostics and controller states, then complete the authorized safety validation.
06
CUSTOMER QUESTIONS

FAQ

Q01

What information should accompany a 6ES7518-4FP00-0AB0 enquiry?

Provide the 0AB0 label, firmware, project and TIA versions, safety signature, memory card, network topology and quantity.

Q02

Is 6ES7518-4FP00-0AB0 interchangeable with 6ES7518-4FX00-1AC0?

Not by CPU family alone. The FX article is an MFP bundle with additional runtime entitlements and a different controlled supply identity.

Q03

Why must all four interfaces be documented for 6ES7518-4FP00-0AB0?

Each interface can carry a different engineered role, address plan and device population that must survive replacement.

Q04

What should be checked before loading a project into 6ES7518-4FP00-0AB0?

Confirm firmware compatibility, memory-card status, project version, safety signature and the approved certificate or access configuration.

Q05

What closes a 6ES7518-4FP00-0AB0 controller exchange?

Stable communications, correct diagnostics, matching safety signature and completion of the approved safety proof tests are required.

INDUSTRIAL SOURCING SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact records support a cleaner quotation

IndustryParts prepares 6ES7518-4FP00-0AB0 enquiries around the complete manufacturer label, requested quantity and installed-system evidence. Share the application record that distinguishes this execution before a supply proposal is prepared.

Complete label retainedHost context reviewedQuantity linked to the enquiry
IndustryParts industrial parts support and order verification
ENQUIRY INFORMATION

Request a model-specific quotation

Send the complete 6ES7518-4FP00-0AB0 label, requested quantity and delivery destination.

You May Also Like