Home>PLC>Siemens 6FC5247-0AA00-0AA3 SINUMERIK 840D/DE NCU Box

Hot Categories

Siemens 6FC5247-0AA00-0AA3 SINUMERIK 840D/DE NCU Box

Siemens 6FC5247-0AA00-0AA3 SINUMERIK 840D/DE NCU Box

Item NO.: 3796112

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6FC5247-0AA00-0AA3 SINUMERIK 840D/DE NCU Box
  • Item NO.3796112
  • Weight3.8400 kg = 8.4658 lb = 135.4520 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-10-16
SINUMERIK 840D/DE | NCU ENCLOSURE | POWER, BATTERY AND FAN

Siemens 6FC5247-0AA00-0AA3 SINUMERIK 840D/DE NCU Box

An NCU enclosure assembly for supported SINUMERIK 840D/DE NCU 561, 571, 572 and 573 variants.

ManufacturerSiemens
Exact model6FC5247-0AA00-0AA3
Product typeSINUMERIK 840D/DE NCU Box
01

Product Identification

6FC5247-0AA00-0AA3 is the Siemens SINUMERIK 840D/DE NCU box. It is the module carrier and enclosure for the listed NCU generations and includes the power supply unit, battery and fan assembly.

The NCU box contains the rack and cable-distribution structure plus guide rails for the NCU and service assemblies. The installed NCU variant and all retained data remain separate compatibility items.

02

Engineering Data

Manufacturer Siemens
Exact article number 6FC5247-0AA00-0AA3
Product type SINUMERIK 840D/DE NCU box
Included service elements Power supply unit, battery and fan
Supported NCU groups NCU 561.2/.3/.4/.5; 571/571.2/.3/.4/.5; 572/572.2/.3/.4/.5; 573.2/.3/.4/.5
Construction NC rack with cable distributor and sheet-metal enclosure
Lifecycle status Product cancellation
EAN 4025515019879
UPC 040892739053
Country of origin Germany
RoHS status Not RoHS-compliant
Quantity unit 1 piece
Dangerous-goods handling Yes — follow the applicable transport report
03

Functions

01

Provides the mechanical carrier and guided enclosure for the supported NCU module.

02

Distributes the internal cable connections required by the NCU rack arrangement.

03

Houses the power, battery and fan service components included in the article.

04

Maintains the physical system boundary between the NCU, rack and surrounding SINUMERIK installation.

04

Applications

  • Service replacement in documented SINUMERIK 840D/DE controls using one of the listed NCU variants.
  • Restoration of an enclosure with damaged power, battery, fan, rack or cable-distribution hardware.
  • Machine-tool maintenance where the existing NCU and control data are retained or migrated under the approved procedure.
  • Legacy spare planning that requires the exact NCU-box article rather than a later SINUMERIK platform.
05

Lifecycle

  • Siemens lists 6FC5247-0AA00-0AA3 with product cancellation status, so service availability must be checked per enquiry.
  • Record the installed NCU number, software state, battery condition, fan arrangement and all cable positions.
  • Preserve machine data, PLC data and archives independently of the enclosure exchange.
  • Use the dangerous-goods transport instructions applicable to the battery-containing assembly.

About IndustryParts

https://www.industryparts.com/

NCU-box support keeps enclosure and control data separate

IndustryParts prepares 6FC5247-0AA00-0AA3 enquiries with the installed NCU, included service hardware and archive status clearly identified.

  • Supported NCU recorded
  • Battery and fan state reviewed
  • Machine archives requested
IndustryParts service team
07

FAQ

Q01

Does 6FC5247-0AA00-0AA3 include an NCU processor module?

Siemens describes it as the NCU enclosure with power supply, battery and fan; identify the required NCU separately.

Q02

Which installed identity is most important before ordering 6FC5247-0AA00-0AA3?

Provide the exact NCU 561/571/572/573 variant, enclosure label, machine-control release and photographs of every internal connection.

Q03

Can a newer SINUMERIK enclosure directly replace this NCU box?

Not without a documented migration plan because the NCU generation, rack, wiring, power and software architecture can differ.

Q04

Why must machine archives be secured before changing 6FC5247-0AA00-0AA3?

The enclosure replacement can disturb power, battery and NCU connections; separate backups protect machine and PLC data.

Q05

What checks are required after installing the replacement NCU box?

Verify power rails, fan operation, battery status, NCU startup, PLC/NC data, communications and an approved machine-function test.

Enquiry Information

Send the complete 6FC5247-0AA00-0AA3 label, quantity and destination for an exact enquiry record.

WHATSAPP / PHONE+86 18030175807