01Key Information
Siemens 6FC5373-0AA30-0AA1 is a SINUMERIK 840D sl NCU 730.3 PN that combines CNC, PLC and communications functions in one control unit. The official configuration identifies a PLC 317-3 PN/DP, 3 MB of CNC user memory and 512 KB of PLC user memory. Because the unit belongs to a defined SINUMERIK hardware and software generation, replacement work must preserve the complete machine archive, option set, memory media and network configuration.
02Functions
Core Functions
- Executes SINUMERIK 840D sl CNC functions and coordinates the machine control sequence.
- Integrates a PLC 317-3 PN/DP for machine logic and distributed automation tasks.
- Provides 3 MB of CNC user memory and 512 KB of PLC user memory.
- Uses 1 GB of DRAM and 1 MB of nonvolatile memory for the documented hardware generation.
- Supports the engineered PROFINET and PROFIBUS architecture of the installed machine.
- Uses internal heat dissipation and requires the specified control-cabinet environment.
Product Identity
- Manufacturer: Siemens
- Model: 6FC5373-0AA30-0AA1
- Product Type: SINUMERIK 840D sl NCU 730.3 PN numerical control unit
- Status: Cancelled since October 1, 2017; spare-part planning required
03Specifications
| Manufacturer | Siemens |
|---|---|
| Article Number | 6FC5373-0AA30-0AA1 |
| Product Designation | SINUMERIK 840D sl NCU 730.3 PN |
| Integrated PLC | PLC 317-3 PN/DP |
| CNC User Memory | 3 MB |
| PLC User Memory | 512 KB |
| DRAM | 1 GB |
| Nonvolatile Memory | 1 MB |
| Maximum Active Power | 374 W |
| Cooling Method | Internal heat dissipation |
| Degree of Protection | IP20 / UL open type; IPXXB with option-slot cover |
| Operating Temperature | 0 to 55 degrees C |
| Transport Temperature | -40 to 70 degrees C |
| Storage Temperature | -25 to 55 degrees C |
| Relative Humidity | 5 to 95 percent |
04Installation
- Confirm the complete article number, hardware revision and SINUMERIK software release before removal.
- Create and verify a complete CNC, PLC, drive and machine-data archive before the outage.
- Record PROFINET names, IP settings, PROFIBUS addresses, topology, licenses and option assignments.
- Inspect the cabinet cooling path and preserve the documented internal heat-dissipation clearances.
- Transfer memory media or licensed options only under the documented SINUMERIK service procedure.
- After installation, validate CNC axes, PLC I/O, safety functions, drives, networks, operator components and the complete machine cycle.
05Lifecycle
- The exact article was cancelled on October 1, 2017 and should be handled through controlled spare-part or migration planning.
- Siemens identifies 6FC5373-0AA30-0AB0 as the successor article for this NCU generation.
- The successor is not an unconditional drop-in replacement; the CNC software baseline, PLC project, licenses, options and machine archive must be checked.
- Retain the original commissioning archive and hardware identification for any repair or replacement.
- Plan the lifecycle decision around the complete SINUMERIK system rather than the NCU article alone.