Siemens 6FC5410-0AY01-0AA0 SINUMERIK 810DE CCU1 PLC314 Control CPU
Provides the central CCU1 control role in the documented SINUMERIK 810DE architecture.
01Key Information
Siemens 6FC5410-0AY01-0AA0 is identified in Siemens documentation as a SINUMERIK 810DE CCU1 control CPU with PLC314. It belongs to the legacy 810DE compact control architecture and must be selected from the complete typeplate, hardware revision and installed machine archive. Public manufacturer documentation located for this exact article does not provide a reliable complete memory, dimension or weight table, so those values are intentionally not inferred from similar CCU variants.
02Functions
Core Functions
- Provides the central CCU1 control role in the documented SINUMERIK 810DE architecture.
- Integrates PLC314 machine-logic functionality for the associated control system.
- Coordinates NC, PLC, operator and peripheral functions defined by the installed machine configuration.
- Uses the machine-specific software, parameters and hardware option set stored for the original control.
- Requires exact connector and peripheral matching because adjacent CCU articles can have different resources.
- Supports lifecycle service only when the original commissioning data and full article identification are available.
Product Identity
- Manufacturer: Siemens
- Model: 6FC5410-0AY01-0AA0
- Product Type: SINUMERIK 810DE CCU1 control CPU with PLC314
- Status: Legacy SINUMERIK 810DE generation; current service status requires confirmation
03Specifications
| Manufacturer | Siemens |
|---|---|
| Article Number | 6FC5410-0AY01-0AA0 |
| Product Family | SINUMERIK 810DE |
| Control Unit | CCU1 |
| Integrated PLC | PLC314 |
| Product Category | Control CPU |
| System Generation | Legacy compact SINUMERIK architecture |
| Identification Requirement | Complete MLFB and hardware revision required |
| Commissioning Basis | Original NC, PLC and machine-data archive required |
04Installation
- Photograph the full nameplate and document the complete MLFB, hardware status and all fitted options.
- Create a verified backup of NC data, PLC program, machine data, setting data, tools and operator settings.
- Label every connector and record the control, drive, I/O and operator-panel arrangement before removal.
- Check replacement hardware against the exact CCU1 and PLC314 system architecture.
- Restore data only under the applicable SINUMERIK 810D/810DE commissioning procedure.
- Validate PLC logic, NC axes, drives, I/O, alarms, references, limits and the complete machine cycle.
05Lifecycle
- This article belongs to the legacy SINUMERIK 810DE CCU1 generation.
- Current Siemens service, repair or spare-part availability must be confirmed for the destination and requirement.
- No automatic successor is stated because software, memory, peripherals and machine options determine migration scope.
- Do not copy specifications from another CCU1, CCU3 or 810D article with a similar number.
- Preserve the original hardware and complete machine archive until the replacement has passed acceptance testing.