Home>PLC>Siemens 6RY1701-0AA04 Three-Phase Radial Fan Spare

Hot Categories

Siemens 6RY1701-0AA04 Three-Phase Radial Fan Spare

Siemens 6RY1701-0AA04 Three-Phase Radial Fan Spare

Item NO.: 3809299

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6RY1701-0AA04 Three-Phase Radial Fan Spare
  • Item NO.3809299
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-10-26
SIMOREG DC MASTER
DC DRIVE COOLING · 460 V AC · THREE-PHASE FAN

Siemens 6RY1701-0AA04 Three-Phase Radial Fan Spare

A SIMOREG DC MASTER radial-fan spare identified for 460 V AC three-phase cooling service.

01
PRODUCT CONTEXT

Technical Summary

Siemens 6RY1701-0AA04 is a radial fan spare for defined SIMOREG DC MASTER base-drive executions. Manufacturer ordering data identifies the fan supply as 460 V AC, three phase.

Fan selection is tied to the converter current rating and mechanical installation. The 0AA04 suffix must remain visible because nearby 6RY1701 fan codes represent different electrical executions.

Cooling work should preserve rotation, airflow direction, mounting, connector arrangement and the drive thermal-protection path rather than treating the fan as a generic motor.

02
CONTROLLED DATA

Specifications

Manufacturer

Siemens

Exact MLFB

6RY1701-0AA04

Drive family

SIMOREG DC MASTER

Spare type

Radial fan

Fan supply

460 V AC

Supply phases

Three phase

Documented base-drive use

1180 A, 1660 A and 1680 A executions

Selection evidence

Drive MLFB, fan label, mounting and connector record

03
CAPABILITY PROFILE

Features

01

Converter-specific airflow

The fan provides forced cooling for the documented high-current DC drive hardware.

02

Defined electrical execution

The 0AA04 variant is distinguished by its three-phase 460 V AC supply.

03

Mechanical service item

Mounting position, impeller clearance and airflow orientation are part of the replacement check.

04

Thermal protection context

Fan operation must be evaluated with the drive temperature and fault-monitoring functions.

IndustryParts industrial automation support
EXACT-MODEL SUPPLY SUPPORT

About IndustryParts

https://www.industryparts.com/

Traceable handling for 6RY1701-0AA04

IndustryParts keeps the submitted 6RY1701-0AA04 identity, quantity and installed-system evidence together so the proposed supply can be checked before dispatch.

Complete label retained with the enquiry

Host-system evidence reviewed before quotation

Requested quantity tied to the exact model record

04
DECISION MATRIX

Compatibility

CHECKDECISION BOUNDARY
A

Drive current execution

Match the complete SIMOREG base-drive order number and published current class.

B

Electrical supply

Verify actual fan-line voltage, phase sequence, protection and connector or terminal arrangement.

C

Physical envelope

Compare mounting holes, housing clearance, airflow arrow and cable reach before installation.

05
SERVICE PATH

Replacement

BEFORE

Establish the cooling baseline

Record fan label, drive MLFB, rotation arrow, airflow, wiring and any thermal alarms.

FIT

Install without obstruction

Clean the air path, match mounting and phase connections, then inspect impeller clearance.

VERIFY

Observe loaded operation

Confirm rotation, airflow and stable drive temperature during the approved functional test.

06
CUSTOMER QUESTIONS

FAQ

Q01

What electrical identity distinguishes 6RY1701-0AA04?

The manufacturer listing identifies this radial-fan execution for 460 V AC, three-phase supply.

Q02

Can another 6RY1701 fan replace 6RY1701-0AA04 by appearance alone?

No. Supply voltage, phase count, mounting, airflow direction and the supported converter execution all require comparison.

Q03

Which nameplates should accompany a 6RY1701-0AA04 request?

Provide the fan label, complete SIMOREG drive MLFB, rated current, cabinet identifier and clear mounting and connector photographs.

Q04

What should be checked before powering 6RY1701-0AA04?

Inspect free rotation, guards, fasteners, connector security, phase sequence, air-path cleanliness and insulation condition under the approved procedure.

Q05

How is 6RY1701-0AA04 cooling performance confirmed?

Verify correct rotation and airflow, then observe fan current, drive temperature and thermal diagnostics during controlled operation.