Home>PLC>Siemens 6RY1703-0EA02 Field-Supply / Excitation Board

Hot Categories

Siemens 6RY1703-0EA02 Field-Supply / Excitation Board

Siemens 6RY1703-0EA02 Field-Supply / Excitation Board

Item NO.: 3809342

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6RY1703-0EA02 Field-Supply / Excitation Board
  • Item NO.3809342
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-10-26
PRODUCT FAMILYSIMOREG DC MASTER
FIELD EXCITATION HARDWARE · BOARD IDENTITY C98043-A7004-L2

Siemens 6RY1703-0EA02 Field-Supply / Excitation Board

A SIMOREG DC MASTER field-supply assembly identified by the full 6RY MLFB and its associated board record.

01
ASSET RECORD

Product Identification

Siemens 6RY1703-0EA02 is a field-supply or excitation-board spare for the SIMOREG DC MASTER platform. Service references associate the MLFB with board identity C98043-A7004-L2.

This assembly belongs to the motor-field power path. Exact suitability depends on the host converter, field-current requirement, board execution and connector arrangement rather than on the 6RY1703 prefix alone.

Published information for this legacy spare is limited; the page therefore keeps converter ratings and optional configurations outside the record unless they are shown on the installed Siemens documentation.

02
PUBLISHED DATASET

Engineering Data

Manufacturer

Siemens

Exact MLFB

6RY1703-0EA02

Drive platform

SIMOREG DC MASTER

Hardware role

Field supply / excitation board

Associated board identity

C98043-A7004-L2

Circuit context

DC motor field-power path

Selection evidence

Host converter, field data and complete board label

Service boundary

Connector, revision and application records required

03
OPERATING ROLE

Functions

01

Field-power control path

Supports the excitation supply assigned to the connected DC motor field circuit.

02

Board-level identity

The C98043 board marking provides a second traceability point alongside the 6RY catalog number.

03

Converter integration

Operation is coordinated with the SIMOREG control and protection configuration.

04

Maintenance continuity

Exact records reduce the risk of fitting a visually similar but electrically different 6RY assembly.

IndustryParts industrial automation support
EXACT-MODEL SUPPLY SUPPORT

About IndustryParts

https://www.industryparts.com/

Traceable handling for 6RY1703-0EA02

IndustryParts keeps the submitted 6RY1703-0EA02 identity, quantity and installed-system evidence together so the proposed supply can be checked before dispatch.

Suffix and revision kept visible

Installed application boundary documented

Supply record linked to the exact enquiry

04
SYSTEM PLACEMENT

Applications

DC motor excitation service

Replacement planning in an existing SIMOREG drive with a documented motor-field circuit.

Legacy spare verification

Comparison of MLFB, board code, revision and host converter before supply.

Controlled repair workflow

Board diagnosis or exchange under the converter-specific Siemens instructions.

05
MAINTENANCE CONTROL

Lifecycle

CAPTURE

Baseline

Record converter and motor nameplates, field current data, board code, connectors, parameters and fault history.

CONTROL

Reconcile

Confirm exact MLFB and C98043 identity against the host hardware before any transfer.

PROVE

Commission

Check field-circuit continuity and insulation, then verify excitation current and protection response under control.

07
PURCHASE AND SERVICE SUPPORT

FAQ

Q01

What second identity is associated with 6RY1703-0EA02?

Service records associate the MLFB with Siemens board code C98043-A7004-L2; both markings should be captured.

Q02

Can a nearby 6RY1703 catalog number replace 6RY1703-0EA02?

Not by family resemblance. Board function, suffix, revision, connector map and host converter must all agree.

Q03

Which motor information matters for a 6RY1703-0EA02 enquiry?

Provide armature and field nameplate data, required field current and voltage, motor connection drawing and the host SIMOREG MLFB.

Q04

What should be recorded before disconnecting 6RY1703-0EA02?

Capture every plug and conductor, parameter backup, field-circuit protection, board revision and the active fault history.

Q05

How is a replacement 6RY1703-0EA02 field path accepted?

Verify insulation and continuity under the approved procedure, controlled field-current build-up, stable regulation and correct protection response.