Home>PLC>Siemens 6SE7022-6TP60 SIMOVERT MASTERDRIVES Compact PLUS Inverter

Hot Categories

Siemens 6SE7022-6TP60 SIMOVERT MASTERDRIVES Compact PLUS Inverter

Siemens 6SE7022-6TP60 SIMOVERT MASTERDRIVES Compact PLUS Inverter

Item NO.: 3802614

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SE7022-6TP60 SIMOVERT MASTERDRIVES Compact PLUS Inverter
  • Item NO.3802614
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-10-21
ManufacturerSiemens
Exact model6SE7022-6TP60
Product typeSIMOVERT MASTERDRIVES Compact PLUS Inverter
DC-AC
510–650 V DC INPUT | 11 KW | 25.5 A RATED OUTPUT

Siemens 6SE7022-6TP60 SIMOVERT MASTERDRIVES Compact PLUS Inverter

A DC-to-AC Compact PLUS inverter with a documented 11 kW power rating.

01

Product Identification

6SE7022-6TP60 is a Siemens SIMOVERT MASTERDRIVES Compact PLUS DC-AC inverter for a 510 to 650 V DC link.

Siemens operating instructions list an 11.0 kW rating, 25.5 A rated output current and power-section definition value 16 for this article number.

Replacement planning must preserve the complete TP60 execution, control configuration, motor data and cabinet protection design.

02

Engineering Data

Manufacturer Siemens
Exact article number 6SE7022-6TP60
Product family SIMOVERT MASTERDRIVES Compact PLUS
Conversion DC-AC inverter
DC-link range 510 to 650 V DC
Rated power 11.0 kW
Rated output current 25.5 A
Power-section definition value 16
Construction Book / Compact PLUS execution
Successor reference in Siemens spare table 9MC3156-6RF38-2DO0, subject to migration engineering
03

Functions

01

Converts the common DC-link supply into controlled motor power.

02

Operates as a Compact PLUS MASTERDRIVES inverter power section.

03

Uses parameterized motor and control data for the installed axis or process.

04

Maintains a defined 25.5 A power-section identity for configuration checks.

04

Applications

  • Legacy SIMOVERT MASTERDRIVES motor-control cabinets with a 510 to 650 V DC link.
  • Book-format multi-axis arrangements using a shared DC supply.
  • Controlled replacement of an existing TP60 inverter after exact label verification.
  • Migration projects where motor, control, braking and cabinet interfaces are re-engineered together.
05

Lifecycle

  • Treat the unit as legacy equipment and confirm availability, condition and repair scope at quotation.
  • A listed successor does not constitute a drop-in replacement; compare dimensions, terminals, control electronics, motor data and parameter migration.
  • Archive the complete parameter set, option boards, connector assignments and fault history.
  • Perform insulation, power-stage and motor-direction checks under the approved commissioning procedure.

About IndustryParts

https://www.industryparts.com/

Legacy inverter enquiries retain power, control and migration evidence

IndustryParts prepares 6SE7022-6TP60 requests with the exact TP60 identity, parameter archive, option hardware and cabinet interface record.

  • 11 kW / 25.5 A identity retained
  • Parameter archive requested
  • Migration treated as an engineered change
IndustryParts customer support
07

FAQ

Q01

Is the Siemens successor listed for 6SE7022-6TP60 a direct drop-in replacement?

No. Siemens lists a migration reference, but the change requires engineering of voltage range, output rating, mechanics, terminals, control interfaces and parameter transfer.

Q02

What cabinet evidence should accompany a 6SE7022-6TP60 request?

Provide the full nameplate, DC-link supply, control board identities, option modules, motor data, connector photographs and cabinet clearances.

Q03

Why must the power-section definition be checked after 6SE7022-6TP60 service?

The operating instructions associate this inverter with definition value 16; a correct parameter baseline helps prevent a mismatched power-stage configuration.

Q04

What should be backed up before removing 6SE7022-6TP60?

Save the complete drive parameter set, motor identification, technology settings, option-board data, fault history and any machine-specific acceptance values.

Q05

Which tests should precede return to service?

Verify DC-link polarity and insulation, motor phase order, current feedback, direction, controlled acceleration, braking behavior and every affected interlock.

Enquiry Information

Send the complete 6SE7022-6TP60 label, requested quantity and destination for an exact enquiry record.

You May Also Like