Home>PLC>Siemens 6SE7027-2TD84-1HF4 MASTERDRIVES PEU Module

Hot Categories

Siemens 6SE7027-2TD84-1HF4 MASTERDRIVES PEU Module

Siemens 6SE7027-2TD84-1HF4 MASTERDRIVES PEU Module

Item NO.: 3787229

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SE7027-2TD84-1HF4 MASTERDRIVES PEU Module
  • Item NO.3787229
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-10-09
SIMOVERT MASTERDRIVES | PEU POWER CONTROLLER | 72 A

Siemens 6SE7027-2TD84-1HF4 MASTERDRIVES PEU Module

A PEU power-controller service module for 72 A SIMOVERT MASTERDRIVES units with a 510–620 VDC power range.

BrandSiemens
Model6SE7027-2TD84-1HF4
Product TypeSIMOVERT MASTERDRIVES PEU Power Controller Module
01

Product Profile

6SE7027-2TD84-1HF4 is a Siemens SIMOVERT MASTERDRIVES power-controller module in the PEU service family. It is assigned to 72 A units operating from a 510–620 VDC power range.

The module is an internal converter spare rather than a complete stand-alone drive. Match the full host converter, module revision, connectors and cooling arrangement before installation.

02

Technical Data

Manufacturer Siemens
Model 6SE7027-2TD84-1HF4
Product Family SIMOVERT MASTERDRIVES
Product Type PEU power-controller module
Assigned Unit Current 72 A
Power Range 510–620 VDC
Service Position Internal converter power-controller / PEU position
Host Requirement Manufacturer-assigned 72 A MASTERDRIVES execution
Connector Requirement Power-stage, gate-control and feedback connections must match the host
Cooling Requirement Preserve the converter cooling path and thermal interfaces
Protection Requirement Check fuses, power semiconductors, motor circuit and insulation before exchange
Revision Boundary Complete 1HF4 suffix required
Lifecycle Context Legacy MASTERDRIVES service spare
Safety Boundary Qualified high-power drive service with stored-energy controls
03

System Role

  • Controls the assigned converter power stage inside the matching MASTERDRIVES unit.
  • Interfaces with gate-control, feedback and protection circuits in the host converter.
  • Restores the documented PEU service position after fault isolation.
  • Depends on the host control electronics, DC link, cooling and motor circuit.
04

Compatibility

  • Confirm 72 A unit assignment and the 510–620 VDC range.
  • Do not substitute a visually similar PEU or another final suffix without replacement evidence.
  • Match connector keying, mounting points, insulation barriers and cooling contact.
  • Preserve the drive project, parameters and diagnostic history for recommissioning.
05

Applications

  • Corrective repair of a matching 72 A SIMOVERT MASTERDRIVES converter.
  • Legacy drive maintenance where an exact PEU spare is required.
  • Controlled refurbishment after power-stage and insulation diagnosis.
06

FAQ

Which host information is mandatory before ordering 6SE7027-2TD84-1HF4?

Send the complete MASTERDRIVES nameplate, unit current, DC-link class, module position, revision labels and connector photographs.

Can a module with another final suffix replace 6SE7027-2TD84-1HF4?

No automatic equivalence should be assumed; the complete suffix can identify a different service execution or hardware revision.

What tests should precede a 6SE7027-2TD84-1HF4 replacement?

Check the motor and cable insulation, DC link, fuses, gate-drive circuits, current feedback, auxiliary supplies and cooling system.

Which safety sequence applies when handling 6SE7027-2TD84-1HF4?

Isolate every supply, observe the specified discharge time, prove the DC link is de-energized and apply ESD and protective-earth procedures.

How should the drive be accepted after fitting 6SE7027-2TD84-1HF4?

Review diagnostics first, then perform controlled no-load and loaded tests while monitoring current, temperature, switching behavior and protection functions.

You May Also Like