Home>PLC>Siemens 6SE7031-4HE85-1JA0 TSE2 Snubber Circuit Capacitor Module

Hot Categories

Siemens 6SE7031-4HE85-1JA0 TSE2 Snubber Circuit Capacitor Module

Siemens 6SE7031-4HE85-1JA0 TSE2 Snubber Circuit Capacitor Module

Item NO.: 3810544

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SE7031-4HE85-1JA0 TSE2 Snubber Circuit Capacitor Module
  • Item NO.3810544
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-10-27
TSE2 SNUBBER MODULE · DESIGN E · 660–690 V THREE-PHASE

Siemens 6SE7031-4HE85-1JA0 TSE2 Snubber Circuit Capacitor Module

A TSE2 snubber-circuit capacitor spare for design-E feed and infeed/regenerative feedback units at 660–690 V AC.

SYSTEM FAMILYSIMOVERT MASTERDRIVESIdentity / integration / lifecycle
01
ASSET RECORD

Product Identification

Siemens 6SE7031-4HE85-1JA0 is the TSE2 snubber circuit capacitor module specified for SIMOVERT MASTERDRIVES feed and infeed/regenerative feedback units of design E.

The manufacturer data assigns this execution to 660–690 V three-phase systems at 50/60 Hz. The module is selected by the complete MLFB, host-unit design and voltage class.

As an energy-storage component in a power converter, the module requires controlled isolation, discharge verification and exact connection matching before service.

02
PUBLISHED DATASET

Engineering Data

Manufacturer

Siemens

Exact MLFB

6SE7031-4HE85-1JA0

Drive family

SIMOVERT MASTERDRIVES

Module designation

TSE2

Module function

Snubber circuit capacitor module

Compatible unit type

Feed and infeed/regenerative feedback units

Mechanical design

E

System voltage

660–690 V, three phase

Supply frequency

50/60 Hz

Supply scope

Spare module

03
OPERATING ROLE

Functions

01

Switching-transient network

Provides the documented TSE2 snubber-capacitor assembly within the compatible power unit.

02

Voltage-class matching

The module is tied to the 660–690 V design-E execution.

03

Host-unit integration

Connects into the feed or regenerative unit through the approved bus and mounting arrangement.

04

Service identity control

The complete 6SE7031-4HE85-1JA0 MLFB separates this TSE2 from other voltage and frame variants.

04
SYSTEM PLACEMENT

Applications

Feed-unit maintenance

Exact spare replacement in a documented design-E MASTERDRIVES supply unit.

Regenerative-unit repair

Restoration of the approved snubber path in an infeed/regenerative feedback assembly.

Planned legacy inventory

Controlled spare holding for identified 660–690 V equipment.

05
MAINTENANCE CONTROL

Lifecycle

01
Capture

Record host MLFB, 6SE7031-4HE85-1JA0, design letter, voltage class, terminals, bus connections and capacitor condition.

02
Control

Isolate, lock out and verify discharge before transferring the exact TSE2 module.

03
Prove

Inspect torque and insulation, then verify precharge, DC-link stability, cooling and regenerative operation.

EXACT-MODEL INDUSTRIAL SUPPLY

About IndustryParts

https://www.industryparts.com/

Traceable handling for 6SE7031-4HE85-1JA0

IndustryParts keeps the submitted 6SE7031-4HE85-1JA0 identity, requested quantity and installed-system evidence together so the proposed supply can be checked before dispatch.

Suffix and release kept visible

Installed role documented

Dispatch check tied to the enquiry

IndustryParts industrial automation support
07
PURCHASE AND SERVICE SUPPORT

FAQ

Q01

What host equipment is specified for 6SE7031-4HE85-1JA0?

Siemens lists it for design-E feed and infeed/regenerative feedback units in the SIMOVERT MASTERDRIVES family.

Q02

Which electrical class belongs to 6SE7031-4HE85-1JA0?

The published execution is for 660–690 V three-phase systems at 50/60 Hz.

Q03

Can a TSE module from another frame replace 6SE7031-4HE85-1JA0?

No. TSE designation, design letter, voltage class, mounting and host-unit MLFB must all agree.

Q04

What evidence should accompany a 6SE7031-4HE85-1JA0 request?

Provide the host-unit nameplate, design E marking, TSE2 label, voltage rating, connection photographs and failure diagnosis.

Q05

Which safety step is critical before handling 6SE7031-4HE85-1JA0?

Follow the approved lockout and discharge procedure and verify stored energy is absent before touching the capacitor circuit.