Home>PLC>Siemens 6SE7031-7HG84-1JC2 IGD5 Inverter Gating Module

Hot Categories

Siemens 6SE7031-7HG84-1JC2 IGD5 Inverter Gating Module

Siemens 6SE7031-7HG84-1JC2 IGD5 Inverter Gating Module

Item NO.: 3776867

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SE7031-7HG84-1JC2 IGD5 Inverter Gating Module
  • Item NO.3776867
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-09-22
SIMOVERT MASTERDRIVES | IGD5 | HIGH-VOLTAGE POWER SECTION

Siemens 6SE7031-7HG84-1JC2 IGD5 Inverter Gating Module

A gating and inverter-control assembly for a documented high-voltage MASTERDRIVES power-unit execution.

BrandSiemens
Model6SE7031-7HG84-1JC2
Product TypeIGD5 Inverter Gating Module
01

Key Information

6SE7031-7HG84-1JC2 is a Siemens IGD5 inverter gating module for a specific high-voltage SIMOVERT MASTERDRIVES power section. Its identity belongs to the complete unit configuration rather than to a stand-alone control accessory.

The complete suffix must be retained. The nearby 6SE7031-7HG84-1JC1 reference is a different hardware revision and should not be treated as interchangeable without a board-level comparison.

02

Functions

  • Interfaces the power-unit control electronics with the inverter switching devices.
  • Carries the gating and monitoring paths required by the matching high-voltage power section.
  • Preserves the documented IGD5 hardware execution during service of an installed MASTERDRIVES unit.
03

Specifications

Manufacturer Siemens
Article Number 6SE7031-7HG84-1JC2
Product Family SIMOVERT MASTERDRIVES
Module Designation IGD5 inverter gating module
AC Unit Class 3 AC 660 to 690 V, 50/60 Hz
DC-Link Class 890 to 930 V DC
Associated Current Class 171 A
Revision Identifier Final suffix -1JC2
04

Installation

  • Isolate every power source, prove DC-link discharge and apply electrostatic-discharge controls before handling the board.
  • Photograph plugs, fiber or ribbon connections, fasteners and grounding points before removal.
  • Compare the full 6SE7031-7HG84-1JC2 label and board revision with the removed assembly before transfer.
  • Complete static checks and a controlled low-risk commissioning sequence before applying production load.
05

Lifecycle

  • Keep the power-unit nameplate and gating-module label together in the asset record.
  • Store tested spares under dry, ESD-controlled conditions suitable for legacy electronics.
  • Plan modernization from the complete motor, DC-link, feedback and automation architecture.
07

FAQ

Can 6SE7031-7HG84-1JC2 be selected only from the 171 A rating?

No. Voltage class, host unit, connector arrangement and the complete -1JC2 revision must also match.

Is 6SE7031-7HG84-1JC2 interchangeable with 6SE7031-7HG84-1JC1?

Do not assume so. Treat JC1 and JC2 as separate board revisions until the host documentation and hardware markings prove compatibility.

What photographs help identify 6SE7031-7HG84-1JC2?

Send the front and rear labels, connector area, component side, host-unit nameplate and cabinet position.

What safety step is critical before replacing 6SE7031-7HG84-1JC2?

Verify isolation and DC-link discharge using the approved service procedure before touching the power section.

What should be tested after installing 6SE7031-7HG84-1JC2?

Check gate-supply health, diagnostics, enable sequence, current response and operation under a controlled load.

Can 6SE7031-7HG84-1JC2 be quoted without the host drive model?

The article can be identified, but the host model and revision are needed for a defensible compatibility review.