Siemens 6SE7033-5GJ84-1JC0 Module
An IGD7 inverter-gating board identifier for SIMOVERT MASTERDRIVES service and exact host verification.
Key Information
6SE7033-5GJ84-1JC0 is the Siemens IGD7 inverter-gating board order number used in SIMOVERT MASTERDRIVES service. The code must stay tied to the converter frame, voltage class, board position and hardware release.
The board controls the gate-drive path of the matching inverter section. Host nameplate, connector arrangement and firmware records are required before exchange; no ratings are inferred from the board number alone.
Functions
- Provides IGD7 gate-control functions for the matching SIMOVERT inverter section.
- Maintains an exact Siemens board identity for repair and installed-base records.
- Supports controlled replacement when the converter frame, power class and interface records agree.
- Keeps the board revision distinct from other 6SE7033 gating references.
Specifications
| Manufacturer | Siemens |
|---|---|
| Model | 6SE7033-5GJ84-1JC0 |
| Product Family | SIMOVERT MASTERDRIVES |
| Product Role | IGD7 inverter gating board |
| Host Converter | Exact SIMOVERT frame and order number required |
| Voltage / Current | Confirm from host nameplate and service documentation |
| Board Position | Record cabinet position and slot |
| Hardware Release | Record all revision and barcode fields |
| Connectors | Compare gate, control and auxiliary interfaces |
| Handling | ESD protection and controlled discharge required |
Installation
- Capture the converter nameplate, board label, connector positions and fault history before isolation.
- Confirm the IGD7 board position and the matching power-stack interface before removal.
- Use the Siemens service procedure for lockout, discharge and ESD handling.
- After installation, perform diagnostics, inhibited tests and a controlled return to service.
Lifecycle
- Archive parameters, firmware, alarms and machine interlock records.
- Store the board in sealed ESD-safe packaging with edge connectors covered.
- Plan a migration review if the installed MASTERDRIVES platform is reaching end of service.
FAQ
Which SIMOVERT information is needed for 6SE7033-5GJ84-1JC0?
Provide the complete converter order number, voltage class, frame, cabinet position, hardware revision and firmware.
Can another IGD7 board replace 6SE7033-5GJ84-1JC0?
Only after a Siemens or host-specific cross-reference confirms gate interface, revision, firmware and power-stack compatibility.
What should be photographed before removing 6SE7033-5GJ84-1JC0?
Photograph the full board label, connectors, adjacent boards, converter nameplate and every cable marker.
What commissioning risk is highest after a 6SE7033-5GJ84-1JC0 exchange?
Incorrect gate-interface or parameter matching can prevent safe power-stack operation, so diagnostics and inhibited tests must precede motor testing.
How should a spare 6SE7033-5GJ84-1JC0 be stored?
Use dry sealed ESD packaging, protect connectors and keep the board barcode traceable to its host record.