Home>PLC>Siemens 6SE7041-8EK85-0HA0 Rectifier Interface Module

Hot Categories

Siemens 6SE7041-8EK85-0HA0 Rectifier Interface Module

Siemens 6SE7041-8EK85-0HA0 Rectifier Interface Module

Item NO.: 3775208

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SE7041-8EK85-0HA0 Rectifier Interface Module
  • Item NO.3775208
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-09-21
SIMOVERT MASTERDRIVES | PER3 POWER INTERFACE

Siemens 6SE7041-8EK85-0HA0 Rectifier Interface Module

A PER3 / FBG power-interface spare for compatible H- and K-design MASTERDRIVES rectifier units.

BrandSiemens
Model6SE7041-8EK85-0HA0
Product TypeRectifier Interface Module
01

Key Information

6SE7041-8EK85-0HA0 is identified in Siemens service documentation as the PER3 rectifier-interface or FBG power-interface execution for matching SIMOVERT MASTERDRIVES units. The final 0HA0 execution distinguishes it from the similarly named PER2 spare.

Correct selection requires the exact host article, design size and cooling or power-unit arrangement. Connector resemblance alone cannot establish compatibility.

02

Functions

  • Provides the designated power-interface path within the matching rectifier assembly.
  • Supports service restoration while retaining the documented PER3 board execution.
  • Interfaces with the original control and power-section connections of the correct H/K unit.
03

Specifications

Manufacturer Siemens
Article Number 6SE7041-8EK85-0HA0
Product Family SIMOVERT MASTERDRIVES
Module Designation PER3 / FBG power interface
Applicable Hardware Compatible rectifier or regenerative unit
Mechanical Design H and K
Supply Voltage Class 3 AC 380 to 480 V
Supply Frequency 50 / 60 Hz
Product Role Internal service spare
Selection Basis Exact host documentation and board execution
04

Installation

  • Compare the complete 0HA0 board identity with the installed spare-parts list before removal.
  • Discharge the DC link fully and use ESD protection when handling the interface board.
  • Retain connector labels, grounding points and hardware orientation during transfer.
  • Perform controlled energization and verify rectifier, feedback and diagnostic behavior before loading the DC bus.
05

Lifecycle

  • Store board and host-unit records together because the execution suffix is service-critical.
  • Preserve parameter backups and cabinet drawings for future system-level replacement work.
  • Review obsolescence exposure and plan migration before the installed power unit becomes unsupported.
07

FAQ

Is 6SE7041-8EK85-0HA0 the same as 6SE7041-8EK85-1HA0?

No. Siemens documentation identifies different PER executions; the complete suffix must match the host spare-parts record.

What must be photographed before removing 6SE7041-8EK85-0HA0?

Capture the board label, connector positions, grounding points, mounting hardware and the complete supply-unit nameplate.

Can 6SE7041-8EK85-0HA0 be bench-tested as a standalone module?

It is an internal interface spare whose meaningful functional tests depend on the correct host power and control architecture.

What fault data is useful when requesting 6SE7041-8EK85-0HA0?

Provide the diagnostic history, event sequence, DC-link behavior and any evidence of connector, power-section or supply faults.

What should be checked after fitting 6SE7041-8EK85-0HA0?

Check board recognition, internal faults, rectifier response, DC-link charging, feedback signals and controlled operation.

How can a wrong 6SE7041-8EK85-0HA0 substitution be avoided?

Match the full host article and hardware version to the official spare documentation before comparing physical board features.

You May Also Like