Home>PLC>Siemens 6SE7041-8HK85-1HA0 Rectifier Interface Module

Hot Categories

Siemens 6SE7041-8HK85-1HA0 Rectifier Interface Module

Siemens 6SE7041-8HK85-1HA0 Rectifier Interface Module

Item NO.: 3775099

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SE7041-8HK85-1HA0 Rectifier Interface Module
  • Item NO.3775099
  • Weight1.3300 kg = 2.9321 lb = 46.9144 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-09-20
SIMOVERT MASTERDRIVES | HIGH-VOLTAGE PER2

Siemens 6SE7041-8HK85-1HA0 Rectifier Interface Module

A PER2 interface spare for higher-voltage H- and K-design infeed and regenerative supply units.

BrandSiemens
Model6SE7041-8HK85-1HA0
Product TypeRectifier Interface Module
01

Key Information

6SE7041-8HK85-1HA0 is the PER2 rectifier-interface module for designated SIMOVERT MASTERDRIVES infeed and regenerative feedback units. Its ordering code belongs to the higher-voltage host family and must not be confused with the EK version.

The module is an internal spare, not a standalone converter. Safe replacement depends on the host supply unit, its power section and the installed hardware execution.

02

Functions

  • Implements the specified interface between control electronics and the rectifier section.
  • Supports matching infeed or energy-feedback operation in H- and K-design hardware.
  • Maintains the correct board execution for service of a legacy high-voltage MASTERDRIVES unit.
03

Specifications

Manufacturer Siemens
Article Number 6SE7041-8HK85-1HA0
Product Family SIMOVERT MASTERDRIVES
Module Designation PER2 rectifier interface
Applicable Unit Type Infeed / regenerative feedback supply unit
Mechanical Design H and K
Voltage Range 1 3 AC 500 to 575 V, 50 / 60 Hz
Voltage Range 2 3 AC 660 to 690 V, 50 / 60 Hz
Lifecycle Status Cancelled since 10 June 2011
04

Installation

  • Verify the HK article family and the complete host-unit label before opening the converter.
  • Apply high-voltage isolation, DC-link discharge and ESD controls throughout the board exchange.
  • Photograph and label connectors so the interface wiring returns to its original positions.
  • Complete diagnostic, charging, infeed and regenerative tests under the approved service procedure.
05

Lifecycle

  • Maintain a tested spare strategy for critical legacy high-voltage installations.
  • Link the replacement board serial identity to the host-unit service history.
  • Evaluate LV SINAMICS migration with the complete system data before spare availability becomes critical.
07

FAQ

Can 6SE7041-8HK85-1HA0 replace 6SE7041-8EK85-1HA0?

No direct replacement should be made; the HK and EK codes identify different supply-voltage families.

Why is the host nameplate essential for 6SE7041-8HK85-1HA0?

It confirms voltage range, mechanical design, regenerative configuration and hardware execution before the cabinet is disturbed.

Is 6SE7041-8HK85-1HA0 still an active Siemens product?

The official lifecycle record shows cancellation, so availability and migration planning should be handled as legacy support.

What evidence should accompany a 6SE7041-8HK85-1HA0 enquiry?

Send the supply-unit article, serial and version labels, the existing PER2 label, fault history and clear connector photographs.

Which checks follow 6SE7041-8HK85-1HA0 installation?

Verify connector seating, internal diagnostics, charge sequence, DC-link stability, enable logic and regenerative feedback behavior.

Can 6SE7041-8HK85-1HA0 be repaired by general panel personnel?

The exchange is inside high-energy converter equipment and requires qualified drive-service procedures and controlled testing.

You May Also Like