Home>PLC>Siemens 6SE7090-0XX84-0AH2 T300 Technology Board

Hot Categories

Siemens 6SE7090-0XX84-0AH2 T300 Technology Board

Siemens 6SE7090-0XX84-0AH2 T300 Technology Board

Item NO.: 3788600

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SE7090-0XX84-0AH2 T300 Technology Board
  • Item NO.3788600
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-10-11
SIMOVERT MASTERDRIVES | T300 BOARD | STRUC CONFIGURATION

Siemens 6SE7090-0XX84-0AH2 T300 Technology Board

The spare T300 technology board used for configured drive-related technology functions in legacy Siemens drive systems.

BrandSiemens
Model6SE7090-0XX84-0AH2
Product TypeSIMOVERT MASTERDRIVES T300 Technology Board Spare
01

Product Profile

6SE7090-0XX84-0AH2 is the Siemens T300 technology board supplied as a spare for SIMOVERT MASTERDRIVES and documented SIMOREG integration contexts. It adds configured technology functions rather than replacing the complete converter.

The T300 architecture provides sixteen binary inputs, eight binary outputs, seven analog inputs, four analog outputs and two serial interfaces. Its application behavior depends on the STRUC configuration and the installed terminal and cable arrangement.

02

Technical Data

Manufacturer Siemens
Model 6SE7090-0XX84-0AH2
Product Family SIMOVERT MASTERDRIVES T300
Product Type T300 technology board supplied as a spare
Binary Inputs 16
Binary Outputs 8
Analog Inputs 7
Analog Outputs 4
Serial Interfaces 2
Configuration Method Customized configuration using STRUC
Functional Scope Additional drive-related technology functions defined by the project
Companion Hardware Context T300 hardware package uses SC58 and SC60 cables and SE300 terminal strip; confirm what remains installed
Host Equipment Documented SIMOVERT MASTERDRIVES or approved SIMOREG application
Mounting Context Technology-board position in the matched converter architecture
Configuration Record STRUC source, compiled application, parameters and I/O scaling
Lifecycle Legacy spare requiring complete project and host documentation
03

System Role

01

Executes the configured technology application associated with the legacy drive system.

02

Provides binary, analog and serial interfaces for the engineered process function.

03

Links STRUC-defined logic to the converter and external terminal arrangement.

04

Allows board-level service while retaining the original host converter architecture.

04

Compatibility

  • Match the full 6SE7090-0XX84-0AH2 identifier and board revision.
  • Preserve the STRUC project, technology software, parameter set and interface scaling.
  • Record SC58 and SC60 cable routing, SE300 terminals and every external signal.
  • Confirm the converter family, electronics-box slot and adjacent option boards.
05

Applications

  • Winding, tension, synchronization and other configured drive-technology functions.
  • Legacy SIMOVERT MASTERDRIVES systems retaining a T300 project.
  • Documented SIMOREG applications that use the T300 hardware package.
06

FAQ

Why is a STRUC project critical when sourcing 6SE7090-0XX84-0AH2?

The board hardware does not define the plant function by itself; the configured technology application, parameters and I/O scaling create the operating behavior.

What companion items should be checked with 6SE7090-0XX84-0AH2?

Document the SC58 and SC60 cables, SE300 terminal strip, memory or software assets, slot position and all external I/O conductors.

Can a blank 6SE7090-0XX84-0AH2 be installed and commissioned from drive parameters alone?

Not when the application depends on a custom T300 technology program; the controlled STRUC configuration and associated files are required.

How should serial and analog functions be accepted after changing 6SE7090-0XX84-0AH2?

Validate scaling, signal direction, limits, communication framing, fail-safe behavior and the process response under a staged commissioning plan.

What should an enquiry for 6SE7090-0XX84-0AH2 include?

Provide board and converter labels, slot and cable photographs, STRUC project status, terminal drawings, failure symptoms and the required test scope.

You May Also Like