Siemens 6SL3055-0AA00-6AA1 DMC20 DRIVE-CLiQ Hub Module

Siemens 6SL3055-0AA00-6AA1 DMC20 DRIVE-CLiQ Hub Module

Item NO.: 3813069

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SL3055-0AA00-6AA1 DMC20 DRIVE-CLiQ Hub Module
  • Item NO.3813069
  • Weight0.9400 kg = 2.0723 lb = 33.1575 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-10-28
SINAMICS S120 / S220TECHNICAL PRODUCT RECORD
STAR TOPOLOGY · FIVE DRIVE-CLIQ DEVICES · CONTROL-CABINET MOUNTING

Siemens 6SL3055-0AA00-6AA1 DMC20 DRIVE-CLiQ Hub Module

An IP20 DRIVE-CLiQ hub that expands a line into a serviceable star topology inside the control cabinet.

Network expansionFive DRIVE-CLiQ devices
TopologyStar with cascade support
MountingTH 35 standard rail
01
PRODUCT DOSSIER

Key Information

6SL3055-0AA00-6AA1 is the Siemens DMC20 DRIVE-CLiQ Hub Module for SINAMICS drive systems. Six DRIVE-CLiQ sockets are provided so five devices can connect while the remaining path links the hub to the line.

The hub implements a star-shaped DRIVE-CLiQ topology and can be cascaded with a second hub. Removing one connected node does not interrupt data exchange with the remaining nodes, which supports structured service of distributed drive components.

The DMC20 is an IP20 control-cabinet device. Unused interfaces require blanking covers, and every DRIVE-CLiQ component must be included in the functional equipotential-bonding concept.

02
OPERATING ROLE

Functions

A

DRIVE-CLiQ distribution

Collects multiple node connections and forwards them through one DRIVE-CLiQ path.

B

Serviceable branches

Allows an individual branch device to be removed without stopping communication to the other branches.

C

Status indication

Uses a multi-color LED to show hub operating state.

D

Cabinet integration

Mounts on a standard rail with a dedicated electronics supply and protective-conductor point.

03
MANUFACTURER DATA

Specifications

Manufacturer
Siemens
Exact model
6SL3055-0AA00-6AA1
Product designation
DMC20 DRIVE-CLiQ Hub Module
Degree of protection
IP20
Electronics supply
24 V DC (20.4 to 28.8 V)
Current without DRIVE-CLiQ node
0.15 A
Maximum supply cable length
30 m
Protective conductor
M4 screw at housing, 1.8 N·m
Scope note
Supplied without DRIVE-CLiQ cable
Suitability certificate
cULus
IndustryParts industrial automation supply support
DOCUMENTED INDUSTRIAL SUPPLY

About IndustryParts

https://www.industryparts.com/

The hub is supplied with its full topology record

IndustryParts keeps the DMC20 article, branch map, node list and cabinet evidence together so a DRIVE-CLiQ expansion remains traceable.

04
CONTROLLED WORK

Installation

Design the topology

Document the upstream port, five branch nodes, cable lengths and any cascaded hub before installation.

Bond and protect interfaces

Mount on bare bonded metal or provide the specified bonding conductor; cover every unused socket.

Validate each branch

Power the network, confirm the LED state and verify recognition of every DRIVE-CLiQ node without branch-address ambiguity.

05
SERVICE RECORD

Lifecycle

Port map custody

Keep the branch drawing and device serials with the drive project.

Contamination prevention

Retain blanking covers on unused DRIVE-CLiQ sockets during operation and storage.

Cable governance

Use released shielded DRIVE-CLiQ cables and preserve the approved length limits.

07
CUSTOMER QUESTIONS

FAQ

Q01

How many branch devices can connect to 6SL3055-0AA00-6AA1?

The DMC20 uses six sockets to connect five DRIVE-CLiQ devices while maintaining the line connection.

Q02

Can 6SL3055-0AA00-6AA1 be installed outside the control cabinet?

No. DMC20 is the IP20 cabinet version; the DME20 is the external IP67 hub execution.

Q03

What bonding information belongs with a 6SL3055-0AA00-6AA1 installation?

Document the bare-metal mounting or parallel equipotential-bonding conductor for every distributed DRIVE-CLiQ component.

Q04

Can two 6SL3055-0AA00-6AA1 hubs be cascaded?

Yes, Siemens documents a two-hub cascade, but the complete approved topology and cable limits must be retained.

Q05

What should be tested after replacing 6SL3055-0AA00-6AA1?

Confirm supply voltage, LED state, every branch device, unaffected-node communication and the restored topology record.