Home>PLC>Siemens 6SL3120-1TE26-0AA3 SINAMICS S120 60 A Single Motor Module

Hot Categories

Siemens 6SL3120-1TE26-0AA3 SINAMICS S120 60 A Single Motor Module

Siemens 6SL3120-1TE26-0AA3 SINAMICS S120 60 A Single Motor Module

Item NO.: 3749733

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SL3120-1TE26-0AA3 SINAMICS S120 60 A Single Motor Module
  • Item NO.3749733
  • Weight9.0000 kg = 19.8416 lb = 317.4657 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-08-28
  • SINAMICS S120 60 A Single Motor Module
Siemens 6SL3120-1TE26-0AA3 SINAMICS S120 60 A Single Motor Module
SINAMICS S120 | Booksize Motor Module

Siemens 6SL3120-1TE26-0AA3 SINAMICS S120 60 A Single Motor Module

Discontinued 60 A AA3 module with 113 A maximum current and an active AC0 successor.

ManufacturerSiemensModel6SL3120-1TE26-0AA3Product TypeLegacy SINAMICS S120 booksize Single Motor Module

01Overview

Siemens 6SL3120-1TE26-0AA3 is a 60 A internal-air-cooled SINAMICS S120 Single Motor Module from the AA3 generation. The official data sheet specifies 52 A base-load current, 80 A S6 current and 113 A maximum current in a 150 mm-wide enclosure. Siemens states that the product was discontinued on 10 January 2025 and identifies 6SL3120-1TE26-0AC0 as the successor. The successor differs in width, base-load current, peak current, cooling and loss values, so its use requires a complete engineering comparison.

Exact-Model CheckVerify the full suffix, current profile, hardware generation, terminals, firmware, drive project and safety configuration before ordering.

02Specs

Manufacturer Siemens
Article Number 6SL3120-1TE26-0AA3
Product Family SINAMICS S120
Construction Booksize, internal air cooling
DC Link / Electronics Supply 510 to 720 V DC / 24 V DC
Rated / Base-Load Current 60.0 A / 52.0 A
S6 / Maximum Current 80.0 A / 113.0 A
Type Rating at IN / IH 32.0 kW / 28.0 kW
DC-Link Current / Capacitance 72.0 A / 1,410 µF
Motor Connection M6 bolt (X1), 2.5 to 50 mm²
Motor Cable Length 100 m shielded; 150 m unshielded
Cooling-Air Requirement 0.031 m³/s
Power Loss, Typical / Maximum 0.55 kW / 0.62 kW
Protection / Dimensions IP20; 150 x 380 x 270 mm
Official Successor 6SL3120-1TE26-0AC0

03Features

Product Functions

  • Provides the AA3-specific 60 A / 113 A output-current profile.
  • Supports 80 A S6 current at the documented 40 percent duty.
  • Uses a 150 mm housing and 0.031 m³/s cooling-air requirement.
  • Provides an M6 bolted motor connection for conductors up to 50 mm².
  • Supports optimized pulse patterns and extended Safety Integrated functions.
  • Integrates with the S120 control architecture through DRIVE-CLiQ.

Identification

  • Manufacturer: Siemens
  • Model: 6SL3120-1TE26-0AA3
  • Product Type: Legacy SINAMICS S120 booksize Single Motor Module
  • Status: Discontinued spare part

04Applications

  • Exact spare replacement for installed 60 A AA3 motor-module positions.
  • Legacy axes whose drive tuning uses the 52 A base-load and 113 A maximum-current values.
  • Cabinets built around the 150 mm AA3 enclosure and original fan arrangement.
  • Migration projects comparing the AA3 thermal design with the narrower AC0 successor.
  • S120 systems where the complete hardware generation is maintained in the spare-parts record.

05Lifecycle

  • Siemens lists the product as discontinued since 10 January 2025.
  • The official successor is 6SL3120-1TE26-0AC0.
  • The AC0 successor is 100 mm wide and has 51 A base-load and 120 A peak-current values.
  • Review busbar alignment, mounting, cooling, power loss, motor connection, firmware and safety behavior.
  • After migration, verify current limits, thermal performance, motor control, diagnostics and Safety Integrated acceptance.

06FAQ

When was 6SL3120-1TE26-0AA3 discontinued?

Siemens lists 10 January 2025 as the effective discontinuation date.

Which successor is identified for the 60 A AA3 article?

Siemens identifies 6SL3120-1TE26-0AC0 as the successor.

What maximum current belongs to the AA3 generation?

The exact data sheet specifies 113.0 A.

How does its base-load current differ from AC0?

The AA3 value is 52.0 A; the AC0 data sheet specifies 51.0 A.

What thermal load is documented for the AA3 module?

The data sheet lists 0.55 kW typical / 0.62 kW maximum power loss and 0.031 m³/s airflow.

Can the 100 mm AC0 simply occupy the 150 mm AA3 position without review?

No. Mounting, busbars, cable routing, cooling, firmware, safety and drive parameters must all be checked.