Home>PLC>Siemens 6SL3120-2TE15-0AA0 SINAMICS S120 5 A Double Motor Module

Hot Categories

Siemens 6SL3120-2TE15-0AA0 SINAMICS S120 5 A Double Motor Module

Siemens 6SL3120-2TE15-0AA0 SINAMICS S120 5 A Double Motor Module

Item NO.: 3750341

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SL3120-2TE15-0AA0 SINAMICS S120 5 A Double Motor Module
  • Item NO.3750341
  • Weight5.3000 kg = 11.6845 lb = 186.9520 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-08-28
  • SINAMICS S120 5 A Double Motor Module
Siemens 6SL3120-2TE15-0AA0 SINAMICS S120 5 A Double Motor Module
Siemens | First-generation SINAMICS S120 booksize Double Motor Module

Siemens 6SL3120-2TE15-0AA0 SINAMICS S120 5 A Double Motor Module

First-generation 5 A/5 A Double Motor Module retains the original AA0 electrical and thermal profile.

ManufacturerSiemens
Model6SL3120-2TE15-0AA0
Product TypeFirst-generation SINAMICS S120 booksize Double Motor Module
01

Product Profile

Siemens 6SL3120-2TE15-0AA0 is the first-generation internally air-cooled SINAMICS S120 Double Motor Module for two 5 A axes. The original equipment manual documents a 510 to 750 V DC-link range, 2 x 3.64 A base-load current, 2 x 6 A intermittent current and 2 x 10 A peak current. It uses the early 50 mm booksize construction, a 220 µF DC-link capacitance and a 5.3 kg module weight. These values belong to AA0 and must not be replaced with the later 0AD0 threefold-overload data.

Configuration BoundaryVerify the exact suffix, current generation, mechanical design, connectors, firmware, cooling, drive project and safety configuration.
02

Technical Data

Manufacturer Siemens
Article Number 6SL3120-2TE15-0AA0
Product Family SINAMICS S120
Construction First-generation booksize, internal fan
DC Link / Electronics Supply 510 to 750 V DC / 24 V DC
Output Voltage 0 to 480 V AC rms
Rated / Base-Load Current 2 x 5.0 A / 2 x 3.64 A
Intermittent / Peak Current 2 x 6.0 A / 2 x 10.0 A
Rated Power 2 x 2.7 kW
Pulse Frequency without Derating 4 kHz
DC-Link Capacitance 220 µF
DC-Link / 24 V Busbar Capacity 100 A / 20 A
Cooling-Air Requirement 29.6 m³/h
Maximum Ambient without Derating 40 °C
Construction Width 50 mm
03

System Role

Power-Section Functions

  • Feeds two 5 A motor axes from one early-generation power section.
  • Uses the AA0-specific 2 x 10 A peak-current limit.
  • Provides 2 x 6 A for the documented intermittent-duty condition.
  • Carries 220 µF of DC-link capacitance in a 50 mm booksize module.
  • Uses an internal fan with a documented 29.6 m³/h cooling-air requirement.
  • Includes the original DRIVE-CLiQ and dual-motor connection architecture.

Exact Product Identity

  • Manufacturer: Siemens
  • Model: 6SL3120-2TE15-0AA0
  • Product Type: First-generation SINAMICS S120 booksize Double Motor Module
  • Status: Legacy spare article
04

Compatibility

  • Keep the full 0AA0 suffix in the spare-parts record.
  • Do not apply the 0AD0 2 x 15 A maximum-current value to this AA0 article.
  • Confirm the early-generation connector set, DRIVE-CLiQ arrangement and fan assembly.
  • Verify DC-link covers, busbars and 24 V distribution before any generation change.
  • Recalculate cabinet loss and airflow if a newer, lighter module is engineered as a replacement.
  • Recommission both axes and complete safety validation after hardware substitution.
05

Applications

  • Exact service replacement in machines built around the 5 A AA0 generation.
  • Legacy two-axis groups whose drive limits use the original 2 x 10 A peak value.
  • Cabinets dimensioned for the original 5.3 kg power module and fan airflow.
  • Maintenance projects preserving the established 510 to 750 V DC-link design.
  • Migration studies comparing AA0 with later AA3 or D-type modules.
06

FAQ

Which peak current belongs to the 5 A AA0 module?

The original Siemens equipment manual specifies 2 x 10 A.

What DC-link range is documented for this first-generation article?

The AA0 equipment manual specifies 510 to 750 V DC.

How much cooling air is required?

The original data lists 29.6 m³/h.

What is the module weight?

The Siemens equipment manual specifies 5.3 kg.

Can 0AD0 data be used for an AA0 spare record?

No. The D-type 0AD0 has different overload, weight and current-profile data.

What must be checked before migrating away from AA0?

Check connectors, busbars, 24 V distribution, cooling, firmware, current limits and safety functions.

You May Also Like