Home>PLC>Siemens 6SL3136-7TE23-6AA3 SINAMICS S120 Active Line Module

Hot Categories

Siemens 6SL3136-7TE23-6AA3 SINAMICS S120 Active Line Module

Siemens 6SL3136-7TE23-6AA3 SINAMICS S120 Active Line Module

Item NO.: 3760218

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SL3136-7TE23-6AA3 SINAMICS S120 Active Line Module
  • Item NO.3760218
  • Weight10.2000 kg = 22.4872 lb = 359.7944 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-09-04
SINAMICS S120 | 36 kW regenerative cold-plate infeed

Siemens 6SL3136-7TE23-6AA3 SINAMICS S120 Active Line Module

A 150 mm booksize Active Line Module engineered for a regulated SINAMICS S120 DC link and cold-plate heat removal.

BrandSiemens
Model6SL3136-7TE23-6AA3
Product TypeSINAMICS S120 Cold-Plate Active Line Module
01

Overview

6SL3136-7TE23-6AA3 is the 36 kW member of the SINAMICS S120 cold-plate Active Line Module range. It supplies a regenerative booksize DC link while transferring its external power loss into the specified customer cooling surface.

This middle power class uses a wider body and a higher-capacity Active Interface Module than the 16 kW article. Those distinctions must remain attached to the complete order number during engineering and replacement.

02

Specs

Manufacturer Siemens
Article Number 6SL3136-7TE23-6AA3
Product Family SINAMICS S120
Product Type Active Line Module, booksize cold-plate format
Rated Power 36 kW
Nominal Line Supply 380 to 480 V AC, 3 phase, 50/60 Hz
Published Line Range 342 to 528 V AC, 47 to 63 Hz
DC-Link Output 600 V DC, 60 A
S6 Duty / Maximum Power 47 / 70 kW
S6 Duty / Maximum DC Current 79 / 117 A
Input Current at 380 / 400 / 480 V 58 / 55 / 46 A
Electronics Supply 24 V DC; 1.5 A maximum
DC-Link Capacitance 1,410 µF
Total Power Loss 0.67 kW at rated operation
Cold-Plate Loss, Internal / External 0.13 / 0.52 kW
Required Thermal Resistance 0.055 K/W
Compatible Active Interface Module 6SL3100-0BE23-6AB0
Degree of Protection IP20
Operating Ambient 0 to 40 °C without derating; 40 to 55 °C with derating
Installation Altitude Up to 1,000 m without derating; up to 4,000 m with derating
Compliance CE and cULus
03

Features

  • Regenerative Active Line operation supports controlled energy exchange between the plant supply and the S120 DC link.
  • The cold-plate format is optimized for equipment designs with a purpose-built conductive cooling interface.
  • A 150 mm mechanical width separates this article from both the lower and higher cold-plate power classes in the batch.
  • DRIVE-CLiQ communication supports parameter coordination, diagnostics and status exchange with the S120 Control Unit.
  • Integrated busbars and protective-earth points support the documented booksize system assembly.
04

Applications

  • Production machines and motion platforms requiring a regenerative infeed in the 36 kW class.
  • Liquid-cooled or cold-plate cabinet concepts designed to manage the module's internal and external heat paths.
  • Multi-axis S120 groups where stable DC-link conditions support coordinated acceleration and deceleration.
  • OEM line-ups using the matching 150 mm line-side interface and approved protection concept.
05

Lifecycle

  • Preserve the 6SL3136 prefix and full suffix when planning service; a similar power rating does not establish cooling or dimensional compatibility.
  • Keep the documented 150 mm Active Interface Module paired with the system unless an engineering review approves a complete line-side change.
  • Back up the infeed parameters, Control Unit project and DRIVE-CLiQ topology before replacement.
  • Revalidate cold-plate flatness, thermal compound or interface material, fastening torque and protective earth during installation.
06

FAQ

How does this unit differ from 6SL3136-7TE21-6AA3?

This article is the 36 kW, 150 mm model with a 60 A DC output and a different Active Interface Module.

Which Active Interface Module belongs with this power class?

The documented companion is 6SL3100-0BE23-6AB0.

What is the main cooling responsibility for the machine builder?

The mounting surface must provide the required thermal resistance and remove the published external loss.

Does the module support regenerative operation?

Yes. It is an Active Line Module intended for controlled line infeed and suitable energy feedback.

Why must the DRIVE-CLiQ topology be recorded?

The module participates in the configured S120 control network, so topology and project data matter during exchange.

What makes the 0AA3 suffix important?

The complete suffix identifies the ordered hardware version and must be matched during service procurement.

IndustryParts | Industrial automation product enquiries and spare-parts support