Siemens 6SL3210-1KE14-3AF2 SINAMICS G120C Compact Converter
A compact filtered drive with integrated PROFINET communication and Safe Torque Off for standard machinery.
Technical Summary
6SL3210-1KE14-3AF2 combines the power section, control electronics, I/O and network interface in one SINAMICS G120C converter. Its exact suffix identifies a PROFINET version with an integrated Class A filter and an externally supplied control circuit.
The compact construction suits machine designs that need networked speed control without assembling a modular power module and separate Control Unit.
Specifications
| Manufacturer | Siemens |
|---|---|
| Article Number | 6SL3210-1KE14-3AF2 |
| Product Family | SINAMICS G120C |
| Line Supply | Three-phase 380–480 V AC, +10% / −20% |
| Line Frequency | 47–63 Hz |
| Low-Overload Power | 1.5 kW |
| High-Overload Power | 1.1 kW |
| Integrated Filter | Class A |
| Fieldbus | PROFINET |
| Control I/O | 6 DI, 2 DO, 1 AI, 1 AO and motor-temperature input |
| Safety Function | Safe Torque Off |
| Protection | IP20 / UL open type |
| Frame Size | FSAA |
| Product Status | Active |
Features
- Integrated converter architecture reduces the number of separately selected drive components.
- Encoderless vector and configurable V/f control modes support common variable-speed motor duties.
- Front-access I/O and network connections simplify cabinet commissioning and diagnostics.
- External control-power capability supports the intended automation design when main power is unavailable.
Compatibility
- Use with a three-phase motor whose current, thermal data and duty cycle fit the converter selection.
- Connect the unit to a compatible PROFINET controller and retain the device-name and telegram configuration.
- Choose line protection, cable shielding and motor-side accessories from the applicable SINAMICS engineering rules.
Replacement
- Back up parameters, motor data, network identity and safety settings before removing the installed converter.
- Compare the complete MLFB, not only the G120C family and power class, because filter and communication variants differ.
- After exchange, restore the controlled parameter set and validate rotation, ramps, I/O, fieldbus and the safety function.
FAQ
Can 6SL3210-1KE14-3AF2 replace an unfiltered G120C variant?
Only after the EMC concept, leakage-current implications and article-level compatibility have been reviewed; the filter option is part of the ordered construction.
What network information is needed for 6SL3210-1KE14-3AF2?
Provide the PROFINET device name, IP settings, controller hardware configuration, telegram and any topology or redundancy requirements.
Does 6SL3210-1KE14-3AF2 remove the need for a safety review?
No. The integrated safety function must remain wired, parameterized and validated within the machine safety design.
Which records prevent a mismatched 6SL3210-1KE14-3AF2 spare?
Supply the complete nameplate, parameter backup, motor rating plate, panel schematic and communication assignment.
Can an older parameter file be loaded into 6SL3210-1KE14-3AF2 without checking firmware?
The project and device firmware should be checked together before download so that parameters and commissioning tools remain compatible.
What should be tested after installing 6SL3210-1KE14-3AF2?
Verify motor direction, current behavior, ramps, digital and analog signals, network control, fault handling and the documented safe-stop response.
Recommended Models
| EPV-5000Q-PY-4 | 7DO720.7 | C04T8R00PB050M |
| 404D-22TA GR65434U084032K | T150 0T614X11 | XYTRONIX X-15s |
| 1734-IE2C + OB4 + IB8 | NW08N1 | DG60D 5D4XC0F01500 |
| DMV755 149037 | CT10.241 | PS120/240-AC85U |
| PCA/702063/M/200 | INT-1534-M-5-M-111 | 1746-IB32 SLC500 |
| AX345 AX34504A | IC200MDL750J | B74-KIT-BD007 |
| NS100L | M1000/3.0 100407 | BT815-W-12-I-BA1 |
| C3S025V2F11I20T30M00 | DNCB-63-320-PPV-A | Herion 0810100 |
| 1756-OB32 | G50AB045MHBR2C | ABB JA/S 4.230.1 GH Q631 0072 R0111 |
| 6SL3210-1KE17-5EF1 | DPIL/10 | ASK 1/EN |