SINAMICS G120 | FSF unfiltered power stage

Siemens 6SL3210-1PE31-5UL0 SINAMICS G120 PM240-2 Power Module

A 75 kW low-overload / 55 kW high-overload PM240-2 module for 380–480 V systems requiring a separately engineered EMC arrangement.

BrandSiemens
Model6SL3210-1PE31-5UL0
Product TypeUnfiltered PM240-2 Power Module
01

Overview

6SL3210-1PE31-5UL0 is the unfiltered FSF version of the SINAMICS G120 PM240-2 power module. It is intended for installations where filtering and EMC compliance are managed at the cabinet or machine level.

The power stage supplies up to 145 A rated output in low-overload duty and 110 A in high-overload duty. An integrated braking chopper is available for connection to a suitable external braking resistor.

02

Specifications

Manufacturer Siemens
Article Number 6SL3210-1PE31-5UL0
Product Family SINAMICS G120 / PM240-2
Input Supply 3 AC 380–480 V, ±10%, 47–63 Hz
Rated Power, Low Overload 75 kW
Rated Power, High Overload 55 kW
Input Current 140 A LO / 117 A HO
Output Current 145 A LO / 110 A HO
Maximum Output Current 220 A
Pulse Frequency 2 kHz
Output Frequency 0–200 Hz vector / 0–550 Hz V/f
EMC Filter Not integrated
Power Factor 0.95
Efficiency 0.98
Power Loss 1.78 kW
Sound Pressure 68 dB
Cooling Air Requirement 0.153 m³/s, internal air cooling
Motor Cable Limit 300 m shielded / 450 m unshielded
Protection IP20 / UL open type
03

Features

  • The UL0 suffix identifies an unfiltered power module and should be retained exactly in procurement and maintenance records.
  • Published low- and high-overload current values provide separate sizing points for variable-torque and heavier cyclic duties.
  • The internal air-cooling path is sized for the FSF power stage and depends on correct cabinet clearances.
  • A braking chopper is incorporated, while the resistor and its thermal protection remain external engineering items.
  • Vector and V/f output-frequency ranges support a broad selection of industrial motor-control tasks.
04

Applications

  • Drive cabinets using centralized line filtering or another documented EMC solution.
  • 75 kW low-overload fan and pump duties in modular SINAMICS G120 architectures.
  • 55 kW high-overload material-handling and process-machine applications.
  • Retrofit projects that must match an existing FSF unfiltered PM240-2 footprint and cooling plan.
05

Lifecycle

  • Identify the spare as 6SL3210-1PE31-5UL0 rather than substituting the heavier filtered AL0 variant without engineering review.
  • Compare line supply, motor current, overload cycle, pulse frequency and external filter arrangement.
  • Inspect fans, airflow path and cabinet heat removal as part of scheduled drive maintenance.
  • Back up parameters and document the Control Unit, option modules and braking resistor before replacement.
06

FAQ

Does 6SL3210-1PE31-5UL0 contain an EMC filter?

No. 6SL3210-1PE31-5UL0 is the unfiltered FSF article.

What output current is published for 6SL3210-1PE31-5UL0?

The ratings are 145 A low overload, 110 A high overload and 220 A maximum output current.

Is 6SL3210-1PE31-5UL0 the same as the AL0 version?

No. The UL0 model is unfiltered; the AL0 article integrates a Class A filter.

What cooling airflow does 6SL3210-1PE31-5UL0 require?

The official data specifies 0.153 m³/s of internal cooling airflow.

Can 6SL3210-1PE31-5UL0 use long motor cables?

The documented limits are 300 m shielded and 450 m unshielded, subject to the complete installation design.

What should accompany a 6SL3210-1PE31-5UL0 enquiry?

Provide motor data, load duty, supply, Control Unit, EMC solution, cable length, braking details and cabinet conditions.