Home>PLC>Siemens 6SL3210-1SE26-0AA0 SINAMICS S120 PM340 30 kW Power Module

Hot Categories

Siemens 6SL3210-1SE26-0AA0 SINAMICS S120 PM340 30 kW Power Module

Siemens 6SL3210-1SE26-0AA0 SINAMICS S120 PM340 30 kW Power Module

Item NO.: 3764561

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SL3210-1SE26-0AA0 SINAMICS S120 PM340 30 kW Power Module
  • Item NO.3764561
  • Weight17.0000 kg = 37.4786 lb = 599.6574 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-09-08
SINAMICS S120 | FSD filtered power stage

Siemens 6SL3210-1SE26-0AA0 SINAMICS S120 PM340 30 kW Power Module

A 60 A filtered FSD power stage for modular SINAMICS S120 drive systems, with 22 kW high-overload power capability.

BrandSiemens
Model6SL3210-1SE26-0AA0
Product TypeSINAMICS S120 PM340 Filtered Power Module
01

Product Profile

6SL3210-1SE26-0AA0 is a Siemens SINAMICS S120 PM340 Power Module for three-phase 380 to 480 V systems. It provides 60 A rated output current and 30 kW rated motor power in a FSD blocksize enclosure.

The 6SL3210-1SE26-0AA0 configuration is a filtered AA0 version. Its 22 kW high-overload rating, 90 A maximum output current and external braking-resistor connection distinguish the exact power-stage selection.

02

Technical Data

Manufacturer Siemens
Article Number 6SL3210-1SE26-0AA0
Product Family SINAMICS S120 / PM340
Power-stage Format Blocksize, FSD, internal air cooling
Input Supply 3 AC 380–480 V, ±10%, 50/60 Hz
Line-filter Configuration Integrated line filter in the AA0 version
Rated Power 30 kW
High-overload Power 22 kW
Rated Output Current 60 A
High-overload Base Current 48 A
S6 Current, 40% Duty 78 A
Maximum Output Current 90 A
Rated Pulse Frequency 4 kHz
Power Loss 0.69 kW
Cooling Air Requirement 54.9 l/s
Sound Pressure Below 60 dB(A)
Rated Input Current 63 A with line reactor / 72 A without
UL Protection 90 A Class J, 65 kA SCCR
External Braking Resistor Greater than 27 Ω
Maximum Braking-resistor Cable 15 m
Maximum Motor Cable 25 m shielded when applying the documented Category C2 filter arrangement
Degree of Protection IP20 or IPXXB
03

System Role

  • Provides the 60 A, 30 kW AC power stage for one SINAMICS S120 drive axis.
  • Receives control commands from a compatible SINAMICS Control Unit and supplies the connected three-phase motor.
  • Integrated line filter in the AA0 version defines how the power stage participates in the cabinet EMC arrangement.
  • Supports the external braking resistor and the documented overload current profile.
  • Fits the FSD blocksize mechanical position and requires the stated cooling airflow.
04

Compatibility

  • Confirm the installed SINAMICS Control Unit and firmware before replacing the power stage.
  • Keep the AA0 integrated-filter selection consistent with the cabinet EMC design.
  • Match the FSD format, 60 A rated current, line reactor and 90 a class j, 65 ka sccr protection.
  • Use an external braking resistor greater than 27 ω with no more than 15 m of connection cable.
  • Retain motor parameters and recommission the axis after the module exchange.
05

Applications

  • 30 kW drive duties with a 22 kW high-overload profile.
  • Machines requiring 22 kW high-overload motor sizing and a 48 A base-current profile.
  • Modular SINAMICS S120 single-axis drive systems controlled by a compatible Control Unit.
  • Retrofit work where the installed cabinet is engineered for the FSD PM340 format and the AA0 filtered variant.
06

FAQ

What motor rating is assigned to 6SL3210-1SE26-0AA0?

6SL3210-1SE26-0AA0 is rated at 30 kW, with a 22 kW high-overload power rating.

What current profile belongs to 6SL3210-1SE26-0AA0?

6SL3210-1SE26-0AA0 provides 60 A rated current, 48 A high-overload base current, 78 A S6 current and 90 A maximum current.

Is the line filter integrated in 6SL3210-1SE26-0AA0?

Yes. The AA0 suffix identifies the integrated-filter configuration.

What lifecycle information applies to 6SL3210-1SE26-0AA0?

6SL3210-1SE26-0AA0 is handled as a cancelled spare-part article, with product cancellation effective 1 October 2019.

How much cooling air does 6SL3210-1SE26-0AA0 require?

The internally cooled FSD power stage requires 54.9 l/s.

What must a proposed successor to 6SL3210-1SE26-0AA0 preserve?

The engineering review must cover 30 kW and 60 A ratings, overload behavior, filter category, cabinet dimensions, Control Unit compatibility and braking circuit.

You May Also Like