Home>PLC>Siemens 6SL3351-6FE35-0AA1 Control Interface Board

Hot Categories

Siemens 6SL3351-6FE35-0AA1 Control Interface Board

Siemens 6SL3351-6FE35-0AA1 Control Interface Board

Item NO.: 3786111

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SL3351-6FE35-0AA1 Control Interface Board
  • Item NO.3786111
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-10-08
MICROMASTER 430 | FRAME GX | SERVICE CIB

Siemens 6SL3351-6FE35-0AA1 Control Interface Board

A replacement control interface board for the 250 kW, 380–480 V MICROMASTER 430 GX drive execution.

BrandSiemens
Model6SL3351-6FE35-0AA1
Product TypeMICROMASTER 430 Control Interface Board
01

Overview

6SL3351-6FE35-0AA1 is a Siemens replacement Control Interface Board for the MICROMASTER 430 GX power class. Siemens service documentation assigns it to the 6SE6430-2UD42-5GA0 drive execution.

The board is a drive-specific service component rather than a stand-alone controller. Its exact article number, connector pattern and host-drive identity must be retained during maintenance.

02

Specs

Manufacturer Siemens
Model 6SL3351-6FE35-0AA1
Product Type Replacement Control Interface Board
Drive Family MICROMASTER 430
Assigned Host Drive 6SE6430-2UD42-5GA0
Host Power Class 250 kW
Supply Class Three-phase 380–480 V, 50/60 Hz
Drive Current Class 490 A
Frame Size GX
Service Documentation Siemens MICROMASTER 430 GX CIB maintenance instructions
03

Features

  • Restores the specified control-interface function within the assigned MICROMASTER 430 power unit.
  • Uses the original connector and mechanical arrangement documented for the GX chassis.
  • Supports a service replacement workflow that includes ESD control and recommissioning.
  • Preserves the exact FE35-0AA1 execution instead of substituting a nearby current class.
04

Applications

  • Planned repair of the assigned 250 kW MICROMASTER 430 drive.
  • Corrective maintenance after diagnosis isolates the control interface board.
  • Legacy drive support where the original parameter set and application wiring are available.
05

Lifecycle

  • Back up parameters, option settings and fault history before opening the drive.
  • Photograph every plug, ribbon connection, grounding point and board switch before removal.
  • Follow Siemens discharge-time, ESD and safe-isolation instructions for the host converter.
  • Recommission I/O, fieldbus, motor control and protection functions under a controlled test plan.
06

FAQ

Why is the complete host-drive code required for 6SL3351-6FE35-0AA1?

The control interface board is assigned to a specific MICROMASTER 430 power execution; frame and current-class differences can prevent a safe fit.

What should be preserved before replacing 6SL3351-6FE35-0AA1?

Retain the parameter archive, drive nameplate, connector photographs, option-board list, I/O schedule and active fault record.

Can 6SL3351-6FE35-0AA1 repair a drive with a power-stage fault?

Not by itself. Confirm the fault location and test the power section, gate drive, auxiliary supplies and connected motor before changing the interface board.

What ESD controls apply when handling 6SL3351-6FE35-0AA1?

Use a grounded workstation and approved handling methods, and keep the board in antistatic packaging until the converter is safely isolated and ready.

How should a drive be accepted after installing 6SL3351-6FE35-0AA1?

Restore the approved parameter set, check diagnostics and I/O, verify motor identification, then complete a low-risk functional test before production load.