Siemens 6SL3985-6TM00-0AA0 TAS21E Thyristor Electronics
Crowbar-control electronics for a designated SINAMICS GM150 IGBT drive execution.
Product Overview
6SL3985-6TM00-0AA0 identifies Siemens TAS21E thyristor electronics used to control the crowbar in a designated SINAMICS GM150 IGBT system. It is a protection-circuit component within the medium-voltage drive, not a stand-alone converter.
Selection must be tied to the exact GM150 voltage execution, crowbar hardware, wiring and cabinet documentation. Similar TAS21E references exist for other voltage classes.
Performance
- Protection behavior depends on the complete crowbar circuit and drive configuration.
- Correct voltage-class selection is essential because related TAS21E articles serve other GM150 executions.
- Functional acceptance requires the approved medium-voltage service and test procedure.
Technical Details
| Manufacturer | Siemens |
|---|---|
| Article Number | 6SL3985-6TM00-0AA0 |
| Product Family | SINAMICS GM150 |
| Module Designation | TAS21E thyristor electronics |
| Primary Function | Crowbar control |
| Drive Technology | GM150 IGBT |
| Documented Voltage Execution | 2.3 kV |
| Installation Class | Internal medium-voltage drive component |
System Integration
- 2.3 kV GM150 IGBT drive
- Matching crowbar assembly
- Drive protection and control circuits
Applications
- Medium-voltage motor drives
- Critical process-drive protection
- GM150 cabinet maintenance
FAQ
What does 6SL3985-6TM00-0AA0 control?
It is TAS21E electronics for the crowbar-control function in the 2.3 kV SINAMICS GM150 IGBT execution.
Is 6SL3985-6TM00-0AA0 a complete crowbar assembly?
No. It is an internal electronics component used with the matching crowbar and drive protection hardware.
Can another TAS21E reference replace 6SL3985-6TM00-0AA0?
Do not assume so; related articles can target different GM150 voltage classes and cabinet arrangements.
What information is needed to quote 6SL3985-6TM00-0AA0?
Send the drive nameplate, voltage class, module label, crowbar assembly details, cabinet drawings and failure report.
Who should install 6SL3985-6TM00-0AA0?
Qualified medium-voltage drive personnel following the applicable GM150 safety and commissioning procedure.
What should be tested after replacing 6SL3985-6TM00-0AA0?
Validate wiring and insulation first, then complete the specified protection-circuit diagnostics and controlled drive tests.
Recommended Models
| Siemens 6ES5420-5AA11 | 0-500V | WS-C2948G |
| I5CA5P02000VA0000S | TR610 TOP2 | BP15SS 1139818 |
| BFN 3-1-56 | 80T602 | K910B |
| ZE544-005A-840 | ME90L2 | A1L5LPK / C |
| KA67 DAS100L4/TH/IS | 1734-AENTR | 5800-801 CS 12.5-50MM |
| Eaton GHG411 2158115700010 | PA-N 160-20-M10 1313-U1 | UAX-008 8-02-0049/2 |
| SR2 B121B | Schunk 9935816 | QUINT-PS/24DC/24DC/20 2320102 |
| E5504GI | ABB N22E 1SBH141001R2622 | CM-1-536 |
| SEW BW100-006 08217017 | PRO 50 MC-1B | SW 030 8020950 |
| Siemens 6ES7353-1AH01-0AE0 | SA67 DRS90L4BE5/TH | ABB 6125/01-84-500, 2CDG006 115 R0183 |