Siemens 6SN1145-1BA02-0CA1 SIMODRIVE 611 36/47 kW Infeed/regenerative feedback module
A 36/47 kW infeed/regenerative feedback module with internal heat dissipation for a compatible modular drive group.
Product Overview
6SN1145-1BA02-0CA1 is a Siemens SIMODRIVE 611 infeed/regenerative feedback module rated at 36/47 kW. The unit combines closed-loop regulated operation with internal heat dissipation.
This article forms the mains-side energy interface for a compatible 611 drive group. Its exact suffix keeps the power class, contact arrangement and hardware revision distinct from visually similar line modules.
Performance
- 36/47 kW rated infeed/regenerative module.
- Closed-loop regulated energy conversion.
- Internal heat dissipation for the documented cabinet installation.
- Mains protection with normally closed contact.
- Mains-side support for a compatible SIMODRIVE 611 DC-link group.
Technical Details
| Manufacturer | Siemens |
|---|---|
| Article Number | 6SN1145-1BA02-0CA1 |
| Product Family | SIMODRIVE 611 |
| Module Type | Infeed/regenerative feedback module |
| Rated Capacity | 36/47 kW |
| Regulation | Closed-loop regulated |
| Cooling | Internal heat dissipation |
| Mains Interface | Mains protection with normally closed contact |
| Lifecycle | Discontinued legacy article |
| Documented Successor | 6SN1145-1BA02-0CA2 |
System Integration
- Match 6SN1145-1BA02-0CA1 to the installed mains voltage, line reactor, fuses and contactor wiring.
- Confirm total DC-link loading and the connected 611 power-module combination.
- Retain the documented cooling clearances and airflow path.
- Review connector coding, protective interlocks and machine control signals before energization.
- Do not base replacement only on the 36/47 kW rating.
Applications
- Legacy CNC machines using SIMODRIVE 611 modular drives.
- Feed and spindle drive groups with regenerative braking energy.
- Revision-controlled maintenance of existing Siemens 611 cabinets.
- Planned spare support or engineered migration of mature motion systems.
FAQ
Which successor is documented for 6SN1145-1BA02-0CA1?
6SN1145-1BA02-0CA1 is superseded by 6SN1145-1BA02-0CA2; compatibility still requires an installed-system review.
What cooling arrangement belongs to 6SN1145-1BA02-0CA1?
6SN1145-1BA02-0CA1 uses internal heat dissipation; the cabinet airflow and heat-removal path must remain suitable.
Which mains interface must be checked for 6SN1145-1BA02-0CA1?
6SN1145-1BA02-0CA1 requires the mains protection with normally closed contact to be verified against the installed wiring.
Can another 36/47 kW SIMODRIVE module automatically replace 6SN1145-1BA02-0CA1?
No. The complete 6SN1145-1BA02-0CA1 suffix, control version, cooling arrangement, connectors and lifecycle status must all match.
What should be recorded before removing 6SN1145-1BA02-0CA1?
Record DC-link connections, mains contactor wiring, connected power modules, cabinet position and all machine-specific settings associated with 6SN1145-1BA02-0CA1.
How should 6SN1145-1BA02-0CA1 be commissioned after exchange?
After fitting 6SN1145-1BA02-0CA1, verify precharge, DC-link voltage, regenerative operation, protective circuits and machine safety functions before production use.
Recommended Models
| 30-60/48 | IO-SDC1 | J110 |
| ZFN0076.3 | ELCASHI7524E34CAER | 2APS-PSU-60 |
| BS&B 2003 | ABB PM583/1SAP140300R0271 | 6DP1232-8AA |
| Schmidt T170 0T724Y21 | EST 3-12/S1RY | ABB M3AA112MB6 |
| ADC813F | AT-UHD-EX-70-TX | CECX-A-4E4A-V |
| 1762-IQ32T | TRIO-PS/3AC/24DC/20 | QUINT-PS/96-110DC/24DC/10 2905010 |
| BC160NT405-160-V RP-BC-CK20 | CSD230M | 6FM1661-3AB10 |
| Balluff BNS 819-B03-R10-46-11 | E1015D | 4Q2 STV3 S112024 |
| di-soric FSLS 50M 60/3 G3K-BS8 | S402E-C16 2CCS552001R0164 | ABB IRB 930-12/0.85 |
| BK5100 | R166239420 | 6ES5740-0AA11 |